Table 1-7
Compute node rear panel features and connectors
(continued)
Function
Number
* The 5340 Appliance add-in cards are available in multiple configurations. Several
configurations include at least one Fibre Channel host bus adapter card for VMware,
optimized deduplication over Fibre Channel, or tape library connectivity.
In some configurations the Fibre Channel host bus adapter cards are installed into some of
the PCIe slots. If the cards are installed in slots 5 and 6, the configuration supports Fibre
Transport Media Server (FTMS) mode. Port 1 of each card is configured by default as Target,
while port 2 is configured by default as Initiator. If you want, you can configure port 2 on
both cards as Target, and you can configure port 1 on both cards as Initiator.
Note:
Starting with software version 3.1, FTMS is supported on configurations C, D, and
E (8Gb FC HBA). Starting with software version 3.1.2, FTMS is supported on configurations
G, H, and J (16Gb FC HBA).
Note:
You should not bond copper 1 Gb Ethernet ports that are installed in the appliance
chassis with PCIe-based 10 Gb Ethernet Fibre Channel ports.
Veritas appliances may include grounding studs in case your lab environment has
such a requirement. The studs are located on the rear panel of the appliance. You
can use standard grounding practices to connect grounding wires to the studs.
The serial number is located on a vertical bar on the rear panel of the appliance.
Figure 1-7
Serial number location
The ports on the rear panel are color-coded for easy identification.
24
About the Veritas 5340 Appliance
About the appliance compute node rear panel