background image

Installation Guide

Air Quality

Z202025-0R 

Page 1 of 3 

©2013 Veris Industries   USA 800.354.8556 or +1.503.598.4564  / [email protected] 12131 

Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Aerospond, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of  Veris Industries, L.L.C. in the USA and/or other countries.

Other companies’ trademarks are hereby acknowledged to belong to their respective owners.

TM

NOTICE 

•  This product is not intended for life or safety applications.

•  Do not install this product in hazardous or classified locations.

•  Read and understand the instructions before installing

 

this product.

•  Turn off all power supplying equipment before working on it.

•  The installer is responsible for conformance to all applicable codes.

 

No responsibility is assumed by Veris Industries for any consequences arising out of the 

use of this material.

Product Identification

Product Overview

The G Series carbon monoxide detectors measure CO levels and signal control systems to provide an inlet of fresh 
air optimal for the space at a given time. G Series devices are equipped with a relay contact that closes when 
the CO level is below 25 ppm and opens when the CO level is above 25 ppm (when used with a normally closed 
contactor). Removal of the sensor, interruption of power, or cut wires cause the relay circuit to open and start the 
fan. Minimum relay cycle time is 3 minutes to prevent fan short-cycling. 

Audible Alarm:   An 85 dB alarm sounds if the CO level rises above 100 ppm for 30 minutes.

G Series

Carbon Monoxide Transmitter

 and Fan Controller

G

D =  Duct mount
W = Wall mount

 Enclosure

 Auxiliary Alarm Output

 Output

A = Auxiliary Contact
X = None

= Standard

V = Field-selectable,  
         0-5/0-10VDC
M =4-20mA
R = Relay only

S

US or EU

Specifications

Input Power

15-30VDC/24VAC, 0.3A@24VAC

Sensor Type

Digitally profiled metal oxide semiconductor (MOS)

Sensor Life

5-10 years typical, replaceable

Detection Range

0 to 200 ppm

Analog Output

3-wire sourcing, 4-20mA or user selectable 0-5V/0-10V (specify mA 

or V)

Output Scaling

User-selectable 100 ppm F.S. or 200 ppm F.S.

Response Time

2 min 30 sec sample interval cycle

Relay Output

N.O. Form A (SPST) 8A@30VAC/VDC; (Use with N.C. contactor)

Relay Setpoint

25 ppm

High Limit Setpoint

100 ppm for 30 minutes

High Limit Alarm

Audible, 85 dB, resets below 100 ppm (solid-state contact for -AS 

version)

High Limit Contact (-AS Models)

250VAC/DC, 120mA max. Ron 35 

Ω

LED Indicators

Solid Green = Normal; Solid Red = Call for ventilation;
Flashing Green = Sensor life has expired; Flashing Red = High-limit 

alarm

Operating Temperature Range

-20° to 50°C (-4° to 122°F)

Operating Humidity Range

0 to 90% RH non-condensing

Coverage

5000-7500 sq ft typical (465-697 sq m)

Housing

White powder coat over steel