Trouble Shooting Guide 

Fire  sparks  but  pilot 

does not light 

 

No gas to fire, check isolators are open.  
Pipe work blockage, clean out.  
Air not fully purged, re purge supply or wait longer. 
Spark earthing to metal work, reset gap correctly 
Blocked pilot, clean out internally.  

Pilot lights but then 

goes out

 

Severe restriction in gas supply: clear obstruction. 
Faulty thermocouple, replace pilot unit.   
Blocked pilot, clean out. 
Blocked lint gauze, clean. 
Hold control knob in for longer.  
Check control knob does not foul data plate. 
If the pilot will not stay lit there is a problem with dirt, 
the gas supply, or the thermocouple needs replacement. 
Modifications are dangerous and can have a serious  
unseen effect on safety. NEVER MODIFY OR BEND 
THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. 

Fire  does  not  spark 
at pilot 

 

HT lead detached, refit.   
Check the spark gap. 
Faulty piezo unit, replace.   
Debris shorting out electrode, clean.   
Spark shorting to metalwork under tray, realign HT lead. 

Fire runs for a time 
and then cuts off 

 

Loose or faulty thermocouple, rectify.  
Blocked pilot, clean out.  
Dirt or lint in pilot aeration hole or on the lint gauze, 
clean thoroughly.  
If the pilot will not stay lit there is a problem with dirt, 
the gas supply, or the thermocouple needs replacement. 
Modifications  are  dangerous  and  can  have  a  serious  unseen 

effect  on  safety.  NEVER  MODIFY  OR  BEND  THE 
THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. 

Pilot  flame  shrinks 

when fire is on high

 

Poor gas flow to fire, check pressure with fire on high. 
If pressure is low, remove any restriction in pipework or valve. 
Check all isolators are adequately sized and fully open. 
Check meter pressure is adequate. 
If the pilot will not stay lit there is a problem with dirt, 
the gas supply, or the thermocouple needs replacement. 
effect on safety.  
NEVER MODIFY OR BEND PILOT TO STAY ALIGHT.  

Fire  smells  when 
first lit or in use

 

Newness smell from brand new appliance.   
Leakage  occurring.  Carry  out  leakage  test  and  rectify  any 
problems.  Combustible materials used in incorrect positions

.

 

Summary of Contents for Cupello

Page 1: ...ON THE WALL FLUELESS GAS FIRE INSTALLATION USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS SHOULD BE RETAINED BY THE USER FOR FUTURE REFERENCE THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN...

Page 2: ...products to provide a complete combustion system which is intrinsically safe The appliance must be installed by a competent person in accordance with Gas Safety Installation and Use Regulations 1998 o...

Page 3: ...iently ventilated space A minimum of 100cm 2 15 5 in 2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the possibility of draughts e...

Page 4: ...d that the old flue should be partially sealed off to prevent draughts however some ventilation will be required to prevent condensation The appliance is designed to be wall mounted It is possible to...

Page 5: ...in the back panel of the appliance The appliance may be installed with or without a non combustible hearth If a hearth is fitted the size and design may be as desired A non combustible shelf of any d...

Page 6: ...es from within the room which may over a period of time slightly discolour decorative surfaces above the fire Plaster Walls Some types of plastered walls may produce small cracks if there is any conce...

Page 7: ...ply pipe and sleeving In order to avoid unnecessary pressure drops no more than 1 5m of 8mm diameter pipe must be used If a concealed gas connection is to be made the supply pipe should always be slee...

Page 8: ...red which are not supplied with this product These should be constructed from metal and not plastic If a concealed gas connection is to be made ensure the gas supply pipe is in its final position and...

Page 9: ...HIGH setting To commission the appliance the burner pressure must be in accordance with the figures stated in the data section of these instructions The fire is factory set to achieve these pressures...

Page 10: ...ot assembly and the burner tube Do not attempt to remove the pilot injector as this can cause damage 9 Re assemble components 10 Turn on the gas supply and leak test Check pilot and burner for good ig...

Page 11: ...ts they should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals are in good condition before replacing the catalyst New seals will usually be required The per...

Page 12: ...to provide a flow through the firebox The burner is then shut off and a smoke pellet or match introduced at the base of the fire underneath the burner tray Large quantities of smoke will emerge from...

Page 13: ...ean Spark shorting to metalwork under tray realign HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on...

Page 14: ...NOT burn any foreign material on this fire Under no circumstances shall the appliance be used if the glass front door or panel has been removed damaged or is open Do not place any objects on top of th...

Page 15: ...manufacturer for further information before proceeding with installation Clearances to the sides of the appliance are 50mm 2in Clearance to the front of the appliance is 500mm 20in The back of the app...

Page 16: ...ly ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH setting push...

Page 17: ...a replacement part is required please contact your stockist in order to obtain the correct part As our policy is one of continuous improvement and development we hope therefore you will understand we...

Page 18: ...2nd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signed Com...

Page 19: ...19 BLANK PAGE...

Page 20: ...20 VERINE LIMITED 52 Broton Drive Trading Estate Halstead Essex CO9 1HB TEL 01787 472551 FAX 01787 476589 www verine co uk sales verine co uk THIS BOOKLET CONTAINS 20 PAGES CUPELLO 06 06 II UI...

Reviews: