Verine Carmelo 1150 NHWV00RN NG Installation, User And Servicing Instructions Download Page 13

Page 13 of 14 

S

ERVICE AND 

M

AINTENANCE

 

 

WARNING

 

 

This  product  may  use  fuel  effect  pieces  containing  Refractory  Ceramic  Fibre 
(RCF).  This  material  contains  man-made  vitreous  silicate  fibres  along  with 
fibrous  glass  and  mineral  wool.  Excessive  exposure  to  these  materials  may 
cause temporary irritation to eyes, skin and respiratory tract; consequently, it 
makes  sense  to  take  care  when  handling  these  articles  to  ensure  that  the 
release of dust is kept to a minimum.  

 

The  appliance  should  be  serviced  at  least  once  a  year  by  a  CORGI  registered 
engineer. This is the basic procedure. 

Any refractory shapes should be taken off the fire and shaken to remove any debris 
but  should  only  be  cleaned  if  absolutely  necessary.  This  should  be  done  by  gently 
brushing  with  a  soft  brush  in  a  direction  away  from  the  person  and  any  persons 
nearby.  This  operation  should  be  performed  outside  facing  downwind.  A  vacuum 
cleaner 

must

 not be used for this purpose. 

Undo the four screws holding the infill grill in position a lift it out of the firebox. Lift 
the  main  burner  and  the  heat  shield  out  of  the  firebox.  The  gas  supply  should  be 
turned off at the combination pressure test point and isolator fitting. Disconnect the 
control  mount  from  the  gas  supply  and  lift  it  out  of  the  lower  firebox  after 
unplugging the lead from the power supply unit from the electronic control box. 

Empty  the  ceramic  gravel  from  the  burner  on  to  a  clean  surface  and  thoroughly 
clean the burner ports. 

The pilot burner fitted is an oxygen depletion pilot burner and is the primary safety 
device on the appliance. It must therefore be replaced annually. After changing the 
pilot burner operate the spark generator and observe that the spark is satisfactory. 

Lay the control mount assembly on a flat surface and remove, clean and replace the 
main injector. 

Any soot or debris should be removed from the fireplace and flue. The flue should be 
inspected  for  soundness  and  a  smoke  test  performed  as  described  in  the  fitting 
section to check the condition of the flue. 

Replace  the  control  mount  in  position  making  sure  that  the  holes  locate  over  the 
studs  in  the  base  of  the  firebox.  Re-connect  the  gas  supply  and  the  lead  from  the 
power  supply  unit.  Place  the  heat  shield  in  position.  Place  the  burner  in  position 
ensuring  that  the  mixing  tube  locates  in  its  hole  in  the  burner  mount  over  the 
injector.  Carefully  place  the  infill  grill  in  position  with  locating  tabs  engaging  with 
the slots in the front lower part of the firebox and fix in place with the four screws 
removed in paragraph 2. Refill the burner with the ceramic gravel making sure that 
the burner ports between the flame guides down the centre are left completely clear. 
Inserting  a  piece  of  corrugated  cardboard  between  the  flame  guides  will  help  keep 
the  burner  ports  clear  during  this  operation.  Replace  any  refractory  shapes  that 
were in place on the burner. 

8

 

AFTER REFITTING THE APPLIANCE CHECK FOR GAS SOUNDNESS AT ALL GAS 
JOINTS AND TEST FOR SPILLAGE. 

Handset Battery Replacement 

9

 

The  handset  is  powered  by  one  Alkaline  9volt  PP3  size  battery.    If  the  fire  fails  to 
respond  to  the  handset  control  check  that  the  LED  on  the  handset  flickers  whilst 
pressing the “Off” &  the  “Standby”  buttons  at the same  time.   If  the  LED  does not 
light,  the  battery  in  the  handset  requires  renewing.  To  change  the  battery  in  the 
handset,  remove  the  battery  cover  on  the  underside  of  the  handset,  unclip  the 
battery from its connector and put a new one put in its place.  Replace the cover. 

 

 

Summary of Contents for Carmelo 1150 NHWV00RN NG

Page 1: ...NSTRUCTIONS THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS DIRECTIVE Model No NHWV00RN for use with natural gas G20 at a supply pressure of 20mbar Model No NHWV00RP for use with propane G31...

Page 2: ...D OF 2nd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signe...

Page 3: ...illage 9 Briefing the User 10 USERS GUIDE 10 Useful tips recommendations 10 Operation of the fire 11 Lighting the Appliance 11 Cleaning the fire 12 SERVICING MAINTENANCE 13 Spares Parts list 14 Import...

Page 4: ...TS Fitting the Appliance 1a United Kingdom The law demands that all gas appliances are installed by a qualified installer in accordance with the current GAS SAFETY INSTALLATION AND USE REGULATIONS The...

Page 5: ...l at least 12mm in thickness In order to provide a tactile warning to persons approaching the naked flames we strongly recommend that an external hearth or a shelf mounted on the wall beneath the appl...

Page 6: ...g the appliance must have a permanent air vent with an effective open area of at least 100 cm2 The vent must be either direct to outside air or to an adjacent room having a permanent vent of the same...

Page 7: ...orizontal and non combustible If the fire opening is to be elevated the base under the firebox will have to be raised to suit and the masonry above the firebox altered to accommodate the gather 4 The...

Page 8: ...ct the gas supply and remove the control mount 10 The space in front of the lower part of the firebox can be filled with masonry and made good or an infill panel fitted Slide the upper part of the fir...

Page 9: ...y driftwood 2 The refractory pieces may be arranged as desired If the objects on the fire bed become excessively covered in soot they should be removed from the fire or placed in another position COMM...

Page 10: ...s with any fire certain components will become hot in use Care should be exercised when approaching the appliance when it is hot We also recommend that a fireguard conforming to BS 6539 or BS 6778 be...

Page 11: ...tery by pushing the connector on to the terminals Make sure the battery is connected correctly Replace the access cover 2 Using the Handset When using the handset make sure that it is pointed at the i...

Page 12: ...ceiver which is situated just in front of the right hand side of the main burner to the OFF position which is indicated by the symbol O Caution should be exercised as this switch is situated quite clo...

Page 13: ...operate the spark generator and observe that the spark is satisfactory 5 Lay the control mount assembly on a flat surface and remove clean and replace the main injector 6 Any soot or debris should be...

Page 14: ...umber Electronic Control Remote Handset G6R PISOA5A0S5 Motorised Control Valve GV60M1C5A0D5K10L Oxypilot NG models Seagas P4 61 Oxypilot LPG models Seagas P4 58 B 112070 Issue 3 BFM Europe Limited Tre...