background image

Page 1 of 14 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1. 

APPLIANCE DATA – SWITCHCRAFT & SENSOR REMOTE MODELS. 

 
 

 

 

 

Carmelo 1150 

Inset Fire 

 

MODEL NUMBERS: NHWV00RN (NG) & NHWV00RP (LPG) 

 

INSTALLATION, USER AND

 

SERVICING INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS DIRECTIVE 

 

 

Model No. NHWV00RN for use with natural gas (G20) at a supply pressure of 20mbar. 

Model No. NHWV00RP for use with propane (G31) at a supply pressure of 37mbar. 

Both models are suitable for installation within G.B. / I.E. 

 

 

THESE INSTRUCTIONS SHOULD BE RETAINED 

BY THE USER FOR FUTURE REFERENCE

 

Summary of Contents for Carmelo 1150 NHWV00RN NG

Page 1: ...NSTRUCTIONS THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS DIRECTIVE Model No NHWV00RN for use with natural gas G20 at a supply pressure of 20mbar Model No NHWV00RP for use with propane G31...

Page 2: ...D OF 2nd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 3rd SERVICE Serviced by CORGI No Service Date Signed Comments RECORD OF 4th SERVICE Serviced by CORGI No Service Date Signe...

Page 3: ...illage 9 Briefing the User 10 USERS GUIDE 10 Useful tips recommendations 10 Operation of the fire 11 Lighting the Appliance 11 Cleaning the fire 12 SERVICING MAINTENANCE 13 Spares Parts list 14 Import...

Page 4: ...TS Fitting the Appliance 1a United Kingdom The law demands that all gas appliances are installed by a qualified installer in accordance with the current GAS SAFETY INSTALLATION AND USE REGULATIONS The...

Page 5: ...l at least 12mm in thickness In order to provide a tactile warning to persons approaching the naked flames we strongly recommend that an external hearth or a shelf mounted on the wall beneath the appl...

Page 6: ...g the appliance must have a permanent air vent with an effective open area of at least 100 cm2 The vent must be either direct to outside air or to an adjacent room having a permanent vent of the same...

Page 7: ...orizontal and non combustible If the fire opening is to be elevated the base under the firebox will have to be raised to suit and the masonry above the firebox altered to accommodate the gather 4 The...

Page 8: ...ct the gas supply and remove the control mount 10 The space in front of the lower part of the firebox can be filled with masonry and made good or an infill panel fitted Slide the upper part of the fir...

Page 9: ...y driftwood 2 The refractory pieces may be arranged as desired If the objects on the fire bed become excessively covered in soot they should be removed from the fire or placed in another position COMM...

Page 10: ...s with any fire certain components will become hot in use Care should be exercised when approaching the appliance when it is hot We also recommend that a fireguard conforming to BS 6539 or BS 6778 be...

Page 11: ...tery by pushing the connector on to the terminals Make sure the battery is connected correctly Replace the access cover 2 Using the Handset When using the handset make sure that it is pointed at the i...

Page 12: ...ceiver which is situated just in front of the right hand side of the main burner to the OFF position which is indicated by the symbol O Caution should be exercised as this switch is situated quite clo...

Page 13: ...operate the spark generator and observe that the spark is satisfactory 5 Lay the control mount assembly on a flat surface and remove clean and replace the main injector 6 Any soot or debris should be...

Page 14: ...umber Electronic Control Remote Handset G6R PISOA5A0S5 Motorised Control Valve GV60M1C5A0D5K10L Oxypilot NG models Seagas P4 61 Oxypilot LPG models Seagas P4 58 B 112070 Issue 3 BFM Europe Limited Tre...

Reviews: