![Verine ATINA 500 Installation Instructions And User Manual Download Page 2](http://html1.mh-extra.com/html/verine/atina-500/atina-500_installation-instructions-and-user-manual_1004436002.webp)
2
Important Notes – Please read before undertaking the installation
1.
The chimney must be swept before the appliance is fitted.
2.
The Installation Instructions must be adhered to without exception.
LIST OF COMPONENTS
a)
Firebox complete with burner and controls.
b)
Installation, Servicing & Users Instructions
c)
Packet of burner fill; either black granules or limestone pebbles
d)
1 Handset Control unit, 1 off 9 volt battery, 4 off Lithium AA batteries.
e)
Pack containing – 4 magnets, sealing tape, and 8 self-tapping screws for joining the
upper and lower fireboxes.
f)
Fuel pack if ordered.
g)
Trim (as ordered – either XL trim for Atina & Vertex or Portrait for Atina only). The box
containing the trim will include 4 off mounting screws and a pair of disposable gloves.
h)
Four Sided Trim (Optional).
A
PPLIANCE DATA
NABG50RN
NVBG70RN
NABG50RP
NVBG70RP
GAS TYPE
NATURAL GAS
PROPANE
SUPPLY
PRESSURE
20mb
37mb
HEAT INPUT
6.2 kW Net
8.5kW Net
6.4 kW Net
8.1 kW Net
INJECTOR SIZE
Ø
1.9mm
Ø
2.3mm
Ø
1.31mm
Ø 1.46 mm
GAS CONNECTION
8 mm Compression
WEIGHT
16kg
23kg
16kg
23kg
G
ENERAL
I
NSTALLATION
R
EQUIREMENTS
Fitting the Appliance
1
The law demands that all gas appliances are installed by a qualified installer in
accordance with the current
GAS SAFETY (INSTALLATION AND USE) REGULATIONS.
The installation must comply with these installation instructions and all relevant parts
of Local and National Building Regulations or Building Standards (Scotland)
(Consolidation) Regulations and those relevant recommendations of the following
British Standards.
BS 5871: Parts 2 & 3, BS 8303, BS 5440: Parts 1 & 2, BS 1251, BS 6891