13

Note: 

The device monitors each care cycle to ensure that the Interchangeable Head is 

delivering a complete and effective dose. Once the LEDs have passed their guaranteed 100% 

output life where a complete dose cannot be guaranteed, the Interchangeable Head will expire 

and the device will cease to function until the Interchangeable Head is replaced.

The amount of care cycles remaining on an Interchangeable Head 

is displayed both on the device’s Information Display and on the 

Interchangeable Head Life Indicator . When the bottom Interchangeable 

Head Life Indicator Light is flashing and the Information Display is 

displaying “0”, the head needs to be replaced . 

Replacement heads can be ordered directly from Verilux

®

 by calling 1-800-454-4408 or by 

ordering online at www .verilux .com .

Replacing the Interchangeable Heads

Push and release  

latch buttons

To Remove the Interchangeable Head:
Step 1:  

Press and hold both Head Latch Buttons 

shown on each side of the Head .

Step 2:  

Separate the Interchangeable Head from 

the Device Body .

To Install an Interchangeable Head:
Step 1:

  Align the three round plastic posts on the 

back of the Interchangable Head with the 

three post sockets on the Device Body . 

This will also align the square latch holes 

on the interchangeable head with the 

Head Latch buttons on the Device Body .

Step 2:

  Press and hold both Head Latch Buttons 

on each side of the Head .

Step 3:  

Press the Head into place against the 

Device Body and release the Head Latch 

Buttons .

Step 4:  

Press Power Button for approximately 

one second to activate Status Mode (see 

page 7) . The Information Display should 

now display the amount of  

cycles remaining on the new 

Interchangeable Head .

Note:

 If the Information Display shows three dashed lines “---“, the 

Interchangeable Head is incorrectly installed. Repeat the head removal and 

installation process as outlined above. 

Blemish Head

•   414nm of blue light soothes inflamed pores to help restore your skin to a healthy glow . 

Fine Lines and Wrinkles Head

•   660nm of red light helps to reduce the appearance of pimples and blemishes and fine 

lines and wrinkles deep in the skin . 

Summary of Contents for ClearWave CWST2RB

Page 1: ...CWST2RB...

Page 2: ...Overview 6 Accessories 6 Controls and Status Information Indicators 7 Getting Started 8 Operating Instructions 9 Daily Care for your Skin 9 Care Cycle Interruption 10 Charging Mode 11 Cold Protection...

Page 3: ...ining an 80 success rate with light therapy treatment of acne The study showed that blue light in the range of 415nm was effective at eliminating the p acne bacteria that is the most common cause of a...

Page 4: ...vide 600 cycles of use in each The Blemishes Head uses LEDs to emit blue light at 414 nanometer nm to reduce the appearance of pimples and facial blemishes The Fine Lines and Wrinkles Head uses LEDs t...

Page 5: ...ClearWave Soothing Skin System when bathing or standing in water Never use the ClearWave Soothing Skin System if you think the unit has been immersed in water may have become wet or if you have spille...

Page 6: ...t Overview Contents Include a Device Body b Two Replaceable Natural Spectrum Interchangeable Heads c Charging Stand d AC Adapter e Rechargeable Battery factory installed f Protective Eyewear goggles g...

Page 7: ...cing the device in the Charging Stand will also activate Status Mode Interchangeable Head Life Indicator and Battery Life Indicator Information Display Indicators b a d e f c Percentages are approxima...

Page 8: ...e the ClearWave Soothing Skin System on the Charging Stand as shown Be sure that the device is fully seated in the stand Step 3 The Battery Life Indicator Lights will provide information to you on the...

Page 9: ...Do not move the position of the device on your skin Device will beep if removed from skin see page 10 If battery runs low and shuts off unit plug AC Adapter directly into device and continue care cycl...

Page 10: ...0 seconds as a reminder that the care cycle has been interrupted To resume return the device to the same area of your skin and complete the cycle If the time away from your skin exceeds 30 seconds the...

Page 11: ...tand and plug into a 120V grounded electrical outlet Step 2 Place the device on the Charging Stand as shown Step 3 The Battery Life Indicator Lights will provide information to you on the status while...

Page 12: ...e limit and will not continue to operate until a cool down period has been completed If your device enters Heat Protection Mode The Information Display will display HP and the device will beep 10 time...

Page 13: ...de of the Head Step 2 Separate the Interchangeable Head from the Device Body To Install an Interchangeable Head Step 1 Align the three round plastic posts on the back of the Interchangable Head with t...

Page 14: ...ids Care Cleaning and Storage How to Replace the Battery Step 1 With the charger unplugged loosen the screw to the battery compartment using a Philips head screwdriver Step 2 Unplug the battery cable...

Page 15: ...Set the device aside and let it cool down The Problem The Solution The audio signals 10 beeps The Information Display signals Device shuts off in cycle Battery will not hold a charge There are only 6...

Page 16: ...efective parts of this product at no charge to the customer subject to the following limitations This limited warranty does not include any postage freight handling insurance or delivery fees This war...

Reviews: