background image

If you connect a gateway lock to the system, you must enable this feature, set "Unlock time " and by lock 

type "Unlock signal type" (normally open or normally closed). 

33. Type of outgoing button 

Set the target of the outbound button control on the door or gateway, depending on the actual 

installation. Press the exit button to open the door/gate lock. 

34. Status assigned from the washing machine 

Related information about the device will not be displayed until it is connected from the device to the 

system. 

35. Status of the elevator controller 

You can enable/disable the elevator control function. 

Note:

 This feature only works if an elevator control module is installed on the system. 

 

 

36. Setting the security parameters of the input unit

 (depending on the type). 

 

37. Tamper

 

(protective contact when the cover is opened illegally) after activation of this function         

a security contact will be activated in the input station, tamper and if someone tampers with the entrance 

station an alarm will be triggered. The room number must also be set to receive the tamper alarm. 

38. Check the condition of the door 

If this function is enabled the system checks the door status after the longest opening time door. Set 

"Magnetic Contact Type" according to door lock type (normally open or normally closed). Set "Longest 

opening time". Once the door is open the entrance station will check their status for the longest opening 

time set. If the door is not closed after the longest opening time set, a beep will sound from the entrance 

station. 

39. Adjust the volume of the bell speaker. 

You can adjust the volume from 10% to 100% as needed. 

40. Adjust the angle of view 

You can set the angle of view for the entry station. Press the menu to set the angle of view from the entry 

station. Touch the location on the screen where it wants to get closer. 
Press the tracking icon

to exit. Finally, tap the return icon in the upper-left corner of the screen and 

press the confirm settings icon to save the settings. When it rings from the entrance station, the set image 

appears. 

41. Set a password to configure a door lock 

The password can be up to 8 digits, the first digit must not be 0. 

42. Setup mode 

It is turned on by default. If enabled, you can set "Room Address" and "Floor" for monitors on the network. 

If it is turned off at all entry stations network, you will not be able to change the address of any monitor. If 

you don't want users to accidentally change the address of your monitors, turn off this feature on all input 

stations after installation. 

43. System settings 

 

Summary of Contents for VERIA 8277B

Page 1: ...VERIA User s guide Videophone Model VERIA 8277B Please read this manual carefully before use and keep it in case of further need...

Page 2: ...18 System settings 13 19 Setting the password 13 20 Password protection list input stations 13 21 Setting the address of the room 14 22 Set the monitor name 14 23 Setting the name of the entry statio...

Page 3: ...ons may result in damage fromthe device injury to the property or fire Do not bend or unplug the power cord from the mains by force If it is damaged there is a risk of fire or electric shock Do not di...

Page 4: ...h screen 2 wire connection without polarity easy to connect Easy installation as with a conventional traditional 2 wire analog system 256 photos and 16 video files can be stored on integrated memory H...

Page 5: ...heat sources or in a place exposed to the sun is over in the open air with high humidity and condensation of steam in the vicinity of strong sources of electromagnetic on unstable and uneven surfaces...

Page 6: ...pe Hands free 2 Connection 2 wire 4 Sound distortion Less than 3 5 Frequency response 400 3 5K 6 Wire length Maximum 200 meters details in the user manual of the entrance station 7 Audio Digital signa...

Page 7: ...on of analog CCTV 2x models only 8277 8277 W 3 SW1SwitchNo To adjust the contact of the2 wirebus Setting Set the last monitor on the 2 wirebus to set the SW1 to the ON position Other SW monitors to of...

Page 8: ...6 Connectivity options 230V 24V DC adapter 1 1x monitor 1x access station...

Page 9: ......

Page 10: ...2x monitor 1x entry station 4x monitor 2x entry station 5x monitor 1x entry station...

Page 11: ...Connection of external analog cameras Notice Always use a separate power supply for the cameras...

Page 12: ...ons listed on the screen Icon Function Accept Hang Volume Buy Photograph Buy Video Unlock gate or door View or hide icons on the screen Press to answer the call and talk to the visitor After the call...

Page 13: ...e Even broadcasters cannot speak to the broadcaster 3 Call history Press the recent icon in the call menu to view history Press from the list of any call to make a call 4 Favorites Pressing and subdui...

Page 14: ...ress the selected photo to view it Press the icon or to view the previous or next photo Press the video icon on the main menu to go to the video list and press the selected video to start it by pressi...

Page 15: ...rding source The DVR will start recording automatically as soon as it reaches the time of turning on the recording Note 1 The DVR only records video recording without sound 2 A minimum 2G SD card is r...

Page 16: ...you are entering a password for the list of entry stations you must enter a number that does not have the first digit 0 Reset Password 1 Reset your system password If you forget your password to acce...

Page 17: ...e room address on the monitor you must also set a call target for the input station buttons Settings Select the button 1 address menu in your input station settings and set the room address of the mon...

Page 18: ...he longest opening time door Set Magnetic Contact Type according to door lock type normally open or normally closed Set Longest opening time Once the door is open the entrance station will check their...

Page 19: ...recording is automatically made When calling from the entry station both photos and video recordings are automatically taken 4 Brightness Low Normal High Adjust the brightness of the screen 5 Alarm cl...

Page 20: ...try stations View Edit You must enter the correct password to enter the input station settings Cancel Button address to set the target address of button calls to the input station Private device If en...

Page 21: ...Update the program Note In a standby or DVR calendar the device will be in screen saver state if no operation is performed within 4 hours Warranty SAFE HOME europe s r o as a supplier guarys to the o...

Page 22: ...Website www veria eu SAFE HOME europe s r o reserves the right to modify and change product specifications without notice All materials are carefully inspected but the company SAFE HOME europe s r o i...

Reviews: