background image

                                                                                                                 

itself. 

4.

 

Can set the machine at a high place(With hanger)or on the ground. DO not spray 
fog to people directly and lean angle should less than 15 

5.

 

Often check whether there has enough fog liquid in machine. The operation will 
make big damage to the machine if there has no fog liquid. 

6.

 

If the fog is small, plum has noise or there has no fog , Please power off and 
check fog liquid, fuse the connector of remote console and power plug. If the

 

problem could not be solved after check these parts, Please stop check and send 
it back to distributor for repair. 

Repair: 
 

   Please clean the fog machine timely to avoid the damage of spare and decrease 

the repair charge. 

  Don’t make the fog machine be dirty. Screw the cover of liquid can after add fog 

liquid. 
    After about 40hours continually use, Please use 80% distilled water and 20% vinegar 
to clean the dirty in refractory pipe. 
    Disassemble the spray mouth and use vinegar to clean it to keep expedite before 
heat . 

        Reequip the spray mouth after cool and add fog liquid for next using.