![Verderflex Vantage 3000 C Operating Manual Download Page 35](http://html1.mh-extra.com/html/verderflex/vantage-3000-c/vantage-3000-c_operating-manual_1003799035.webp)
Vantage 3000 P
Version 3.4v-01/2019
35 | Page
15 Appendix
Pump Specifications
15.1 Specification Ratings
Size
Value
Operating temperature
+5 °C to +40 °C
(41°F to 104 °F)
Storage temperature
-40 °C to +70 °C
(40°F to 158 °F)
Humidity (non-condensing)
long—term ≤ 80 %
Maximum altitude
Setup height above sea level ≤
2000 m (6560 ft)
Power consumption
<230 W
Supply voltage
100-240 VAC
50/60 Hz
<230 W
Maximum voltage fluctuation
+/-10% of nominal voltage. A
well regulated electrical mains
supply is required along with
cable connections conforming
to the best practice of noise
immunity
Installation category
(overvoltage category)
II
Pollution degree
2
IP
IP66 to BS EN 60529
dB rating
<70dB(A) @ 1.0m
*
*
Sound pressure level is measured by the responsible body at both
operators position in normal use and at whatever point 1.0m from the
enclosure of the equipment that has the highest sound pressure rating.
Table 1
Specification Ratings