Rev 1.1 Cod. 00.009.125
32
QUANTITY DOSING
When the pump is switched on or the Enable signal (Optional) is received, the pump doses the set quantity of product
(
mL Dos
) with the selected % flowrate (
%Flowrate
).
NB: it is important to define the flowrate of the pump in the
Calibration
menu.
EXAMPLE OF MODIFICATION OF mL Dos.:
In the menu
Dosing
, select by the cursor "
Quantity
"
and press
ENTER
.
In the figure on the left you can see the factory
parameters.
Use the ▼▲ buttons to select the parameter to be
changed and press
ENTER
.
Use the ▼▲ buttons to select the desired value and
press
ENTER
whenever necessary to confirm the
change.
If you want to esc programming and return to
measurement, press the
ESC
button for 3 seconds.
PARAMETERS:
mL Dos:
quantity of chemical to be dosed
%Flowrate:
dosing flowrate
TIMER DOS DOSING
When the pump is switched on or the Enable signal (Optional) is received, the pump doses with an hourly rate, the total
quantity of product (
mL Tot
) over the total hours set (
Total Hours
). At each hour it will dose the quantity result from the
division mL Tot ÷ Total hours (any rest is not dosed). You can choose which days of the week perform the dosing.
The count is reset at midnight every day.
The pump has a clock to set in
Set
up
, page 23.
NB: it is important to define the flowrate of the pump in the
Calibration
menu.
EXAMPLE OF MODIFICATION OF mL Tot.:
In the menu
Dosing
, select by the cursor "
Timer
Dos
" and press
ENTER
.
In the figure on the left you can see the factory
parameters.
Use the ▼▲ buttons to select the parameter to be
changed and press
ENTER
.
Use the ▼▲ buttons to select the desired value and
press
ENTER
whenever necessary to confirm the
change.
If you want to esc programming and return to
measurement, press the
ESC
button for 3 seconds.
PARAMETER:
mL Tot:
total amount of chemical to be dosed in one day
Total hours:
total number of hours during which the pump has to dose
M T W T F S S : M
onday;
T
uesday;
W
ednesday;
T
hursday;
F
riday;
S
aturday;
S
unday the "x" enables dosing
x x x x x x x
The hours count starts from the first daily switching on of the pump (if the pump does not have the enable) or
from the first daily reception of the Enable signal (if the pump has the optional of Enable and if this is active in
the Set Up menu).