CONNECTIONS
A -
Power cable, 90-250V-50-60Hz
B -
Enable input (dosing consent)
(110Vac; 230Vac; upon request 24V).
OPTIONAL
C - Alarm
output connector (3 and 4 contacts).
( 5A 250Vca/30Vdc)
NORMALLY OPEN.
OPTIONAL
.
D -
Level probe connector (3 and 4 contacts).
OPTIONAL
.
E -
Connector for mA input
(contacts 3 (+) and 4 (-)).
F -
ON_OFF switch.
OPTIONAL
DEFAULT SETTINGS
PASSWORD
= Not programmed
Delay On
: 0 minutes
Enable (optional)
: active
Broken Hose (optional)
: active
Dosing:
mA
mA Min:
4.0mA
% Min:
10%
Dos.Min:
deactive
mA Max:
20.0mA
% Max:
100%
Dos.Max:
active
DEFAULT SETTINGS RESTORE
3sec
Keep pushing for 3 seconds the
ENTER / MENU
button to
enter into the programming menu.
Move the cursor > to Utility by pressing
▼.
Push
ENTER
button to enter the submenu.
Push ▼ button to move the cursor to “Reset”.
Push
ENTER
button
to confirm
.
By pushing the ▼ button choose “YES” to confirm and push
ENTER
button.
Automatically the pump restores the factory settings.
Press the
ESC
button for 3 seconds to exit programming.