Appendix F 

Breakout Box 

            Vantage 5000

Version 1.6v-05/2019 
Print-No. 01

Peristaltic Cased Tube Pump      

Summary of Contents for Verderflex Vantage 5000

Page 1: ...Appendix F Breakout Box Vantage 5000 Version 1 6v 05 2019 Print No 01 Peristaltic Cased Tube Pump...

Page 2: ...Appendix F 1 6v 05 2019 2 Page Version 1 6v 05 2019 Print No 01 Vantage 5000...

Page 3: ...akout Box 1 1 Installing the Breakout Box 1 1 1 Parts for Reference 1 1 2 Installation Instructions 1 2 Functionality 1 3 Voltage Supplies 1 4 Applied Voltage Signals 1 5 Volt free Signals 1 6 Output...

Page 4: ...to allow the user to make easy connections to all the remote input output lines on the 25 WAY Remote I O Connector on the back of the Vantage 5000 For the connector number s function of the 24VDC bre...

Page 5: ...POSE OUTPUT 4 Output 1 Normally Closed 2 Normally Open 3 Common P12 ANALOGUE IN Input 1 0 10V Input 2 0V Analogue Ground 3 4 20mA Input P13 GENERAL PURPOSE OUTPUT 2 Output 1 Normally Closed 2 Normally...

Page 6: ...PURPOSE OUTPUT 4 Output 1 Normally Closed 2 Normally Open 3 Common P12 ANALOGUE IN Input 1 0 10V Input 2 0V Analogue Ground 3 4 20mA Input P13 GENERAL PURPOSE OUTPUT 2 Output 1 Normally Closed 2 Norm...

Page 7: ...out Box 24 VDC 1 115 VAC 1 2 Breakout Board Fixing Assembly M4 x 8 4 3 Gland Blanking Plugs with Retaining Nuts 4 4 Bulkhead Cable Glands with Retaining Nuts 4 5 5 6 mm x 4 40 UNC D Type Connector Fix...

Page 8: ...nal cables through the glands Fix the breakout board back into the breakout box and tighten the cable retaining grommet nuts 5 Attach the 25 WAY Remote I O Connector to the back of the Vantage 5000 wi...

Page 9: ...is 10 Function Connector Number Description Graphic 24V Pump Supply INPUT P14 In order to use the break out box a 24V Pump Supply must be connected through P14 This can either be supplied through P15...

Page 10: ...e signal is switched ON the LED D1 will light up NOTE This function is applicable for both 24 VDC and 115 VAC MANUAL AUTO P2 will enable the remote I O and enable the user to use the remote start stop...

Page 11: ...tor Number Description Graphic Stop P8 will turn ON the relay and drive the pump stop signal which will allow the pump to start the signal will respond dif ferently depending on the settings in Append...

Page 12: ...d together on P4 the pump will respond to a bund detection event and stop the pump when the signal is switched ON the LED D4 will light up Product Destination Full P5 when pins 1 and 2 are shorted tog...

Page 13: ...box for the user to wire into Function Connector Number Description Graphic Output 1 P19 when the signal is switched ON the LED D19 will light up Output 2 P13 when the signal is switched ON the LED D1...

Page 14: ...Appendix F 1 6v 05 2019 14 Page 1 6 Output Signals Continued Function Connector Number Description Graphic Output 4 P10 when the signal is switched ON the LED D10 will light up Table 7 Output Signals...

Page 15: ...hould be kept separate to the 0V analogue rail NOTE The nominal maximum voltage for 0 10V Input is 10V and the nominal maximum current for 4 20mA Input is 20mA For an accidental higher voltage current...