INSTALLATION
Tighten Fasteners Before Setup
Before using the pump for the first time,
check and retorque the housing bolts (23).
Also the valve stops of the discharge valves
(09) have to be checked. Also after the first
day of operation, after periods of important
temperature
fluctuations, after transport, after
dismantling of the pump and after periods
when the pump hasn’t been working the
stops, plugs and housing bolts have to be
checked. For the housing bolts please use
the torque values as mentioned on page 22.
Figure 1 showing the installation of the pump
A Air Control pro unit consists of:
- On/of valve
- Pressure regulator
- Throttle valve
- Soft start valve
B Isolating valve
C Discharge gauge
D Suction gauge
E Flexible connection
A
E
E
C
B
B
D
Recommended installation drawing
PLEASE CHECk THE ADDITIONAL DELIVERED
EXPLODED VIEW FOR ALL POSITION NumBERS