background image

Operation

Verder HI-CLEAN 

Diaphragm Pump

Model VA-2H80HE

For transfer of fluids in sanitary applications. Not approved for use in European explosive 

atmosphere locations. For professional use only. 

6.9 bar (0.7 MPa, 100 psi) Maximum Fluid Working Pressure 

6.9 bar (0.7 MPa, 100 psi) Maximum Air Input Pressure

Important Safety Instructions. 

Read all warnings and instructions in 

this manual before using the 

equipment. Save these instructions.

812.0062

Rev A 

EN

Summary of Contents for HI-CLEAN VA-2H80HE

Page 1: ...e in European explosive atmosphere locations For professional use only 6 9 bar 0 7 MPa 100 psi Maximum Fluid Working Pressure 6 9 bar 0 7 MPa 100 psi Maximum Air Input Pressure Important Safety Instructions Read all warnings and instructions in this manual before using the equipment Save these instructions 812 0062 Rev A EN ...

Page 2: ...r Exhaust Ventilation 11 Operation 12 Pressure Relief Procedure 12 Sanitize the Pump Before First Use 12 Start and Adjust the Pump 13 Pump Shutdown 13 Maintenance 14 Lubrication 14 Flushing and Storage 14 Routine Cleaning of Product Contact Section of Pump 14 Tightening Connections 14 Technical Specifications 15 Dimensions 15 Performance Chart 16 Technical Data 17 Customer Services Guarantee 19 Re...

Page 3: ...nding instructions Keep work area free of debris including solvent rags and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded fluid lines Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are anti static or conductive Stop operation immediately if static sparkin...

Page 4: ... Call your distributor for information Route fluid lines and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend fluid lines or use fluid lines to pull equipment Keep children and animals away from work area Comply with all applicable safety regulations TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in t...

Page 5: ...umber VA 2H80HE XPSTTFTSD8SB21 VA 2H 80HE X P ST TF TS D8 SB 21 Pump Model Pump Size Wetted Parts Air Section Seats Balls Diaphragms Connections Options Certifications Pump Model Pump Size Wetted Parts Material Air Section Material Seat Material VA 2H 80HE 80 mm X High Sanitation 3 A 0 8 μm P Polypropylene SB Stainless Steel Buna N gasket SE Stainless Steel EPDM gasket Y Pharmaceutical 0 5 μm ST S...

Page 6: ...FDA compliant and meet the United States Code of Federal Regulations CFR Diaphragm Ball Seat Material Fluid Temperature Range Fahrenheit Celsius FKM Fluoroelastomer VT 40 to 275 F 40 to 135 C Polychloroprene check balls NE 0 to 180 F 18 to 82 C EPDM overmolded diaphragm EO 40 to 275 F 40 to 135 C PTFE overmolded diaphragm TO 40 to 180 F 4 to 82 C PTFE check balls 40 to 220 F 4 to 104 C 2 piece PTF...

Page 7: ...re not for use with flammable fluids Follow your local codes and regulations Pump Connect a ground wire and clamp as shown in FIG 1 Loosen the grounding screw W Insert one end of a 1 5 mm 12 AWG or thicker ground wire X behind the grounding screw and tighten the screw securely Connect the clamp end of the ground wire to a true earth ground To order a ground wire and clamp order part number 819 015...

Page 8: ...he fluid pressure The fluid outlet pressure will be the same as the setting of the air regulator b Locate one bleed type master air valve B close to the pump and use it to relieve trapped air Locate the other master air valve E upstream from all air line accessories and use it to isolate them during cleaning and repair c The air line filter F removes harmful dirt and moisture from the compressed a...

Page 9: ...actors 1 Reduce vapor pressure Decrease the temperature of the pumped liquid 2 Increase suction pressure a Lower the installed position of the pump relative to the liquid level in the supply b Reduce the friction length of the suction lines Remember that fittings add friction length to the lines Reduce the number of fittings to reduce the friction length c Increase the diameter of the suction line...

Page 10: ...d E Master air valve for accessories F Air line filter G Flexible fluid suction line J Fluid drain valve required not supplied K Fluid shutoff valve required not supplied L Flexible fluid outlet line M 3 4 npt f air inlet provided V Air pressure gauge required not supplied Items not provided unless noted E F B C A K L J G M V FIG 2 Typical Floor Mount Installation ...

Page 11: ...nductive grounded container U at the end of the air exhaust line to catch fluid in case of a diaphragm rupture See FIG 3 FIG 3 Venting Exhaust Air Be sure the system is properly ventilated for your type of installation You must vent the pump air exhaust to a safe place away from people animals food handling areas and all sources of ignition when pumping flammable or hazardous fluids Diaphragm rupt...

Page 12: ... pump was built and tested using a food grade lubricant Properly sanitize the pump before first use The user must determine whether to disassemble and clean individual parts or simply flush the pump with a sanitizing solution To simply flush the pump with a sanitizing solution follow the steps under Start and Adjust the Pump page 13 and Flushing and Storage page 14 To disassemble and clean individ...

Page 13: ...h the following step 8 To prime the pump slowly increase air pressure with the air regulator C until the pump starts to cycle Do not exceed the maximum operating air pressure as listed in the Technical Specifications page 15 Allow the pump to cycle slowly until all air is pushed out of the fluid lines and fluid exits the outlet line G NOTE If the fluid inlet pressure to the pump is more than 25 of...

Page 14: ...rom the sanitizing solution and drain pump Routine Cleaning of Product Contact Section of Pump NOTE The pump and the system should be cleaned in accordance with your state sanitary standard codes and local regulations 1 Flush the system See Flushing and Storage 2 Follow the Pressure Relief Procedure page 12 3 If disassembly of the pump is required for cleaning refer to the appropriate repair manua...

Page 15: ...ns 812 0062 15 Technical Specifications Dimensions A 98 1 cm 38 63 in B 54 5 cm 21 44 in C 43 8 cm 17 25 in D 13 5 cm 5 33 in E 80 0 cm 31 51 in F 60 5 cm 23 83 in G 37 1 cm 14 6 in H 53 4 cm 21 04 in Weight 56 2 kg 124 lbs ...

Page 16: ...9 5 5 80 0 55 4 1 60 0 41 2 8 40 0 28 1 4 20 0 14 0 0 189 50 379 100 568 150 757 200 946 250 1136 300 0 189 50 379 100 568 150 757 200 946 250 1136 300 9 36 350 8 03 300 6 70 250 5 36 200 4 02 150 2 68 100 1 34 50 0 To find Fluid Outlet Pressure bar psi MPa at a specific fluid flow lpm gpm and operating air pressure bar psi MPa 1 Locate fluid flow rate along bottom of chart 2 Follow vertical line ...

Page 17: ...WR SODVWLF SDUWV r r OXLG GLVSODFHPHQW SHU F FOH JDOORQV OLWHUV 0D LPXP IUHH ᚐRZ GHOLYHU JSP OSP 0D LPXP SXPS VSHHG FSP HLJKW HLJKW HLJKW OO PRGHOV OEV NJ OXLG OXLG OXLG QOHW QOHW QOHW DQG DQG DQG 2XWOHW 2XWOHW 2XWOHW 6L H 6L H 6L H 6WDLQOHVV 6WHHO LQ VDQLWDU ᚐDQJH RU PP 1 PDOH WKUHDG 1RLVH 1RLVH 1RLVH DWD DWD DWD 6RXQG 3RZHU PHDVXUHG SHU 62 ದ DW EDU SVL ᚐXLG SUHVVXUH DQG IXOO ᚐRZ G D DW EDU SVL ᚐ...

Page 18: ...Technical Specifications 18 812 0062 Notes ...

Page 19: ...urchase price WARRANTY DISCLAIMER VERDER has made an effort to illustrate and describe the products in the enclosed brochure accurately however such illustrations and descriptions are for the sole purpose of identification and do not express or imply a warranty that the products are merchantable or fit for a particular purpose or that the products will necessarily conform to the illustration or de...

Page 20: ...nchwad Pune 411019 INDIA e mail sales verder co in www verder co in Italy Verder Italia Via Maestri Del lavoro 5 02100 Vazia Rieti ITALY Tel 39 07 46 229064 e mail info verder it Korea Verder Korea 15 26 Beodeul ro 1362 Paltan myun Hwaseong si Gyeonggi do 18578 KOREA Tel 82 31 355 0316 e mail sales verder kr The Netherlands Verder BV Leningradweg 5 NL 9723 TP Groningen THE NETHERLANDS Tel 31 50 54...