3.0 3508 Controller
Holdback Type
Press scroll
until the display shows 'Holdback Type'. If required, press up
or down
to select 'Off', 'Low', 'High' or 'Band'.
Target Setpoint (Visible only for Rate, Time and Step segments)
Press scroll
until the display shows 'Target SP'. Press up
or down
to set a value.
Ramp Rate (Visible only for Rate segments)
Press scroll
until the display shows 'Ramp Rate'. Press up
or down
to set the
number of degrees per 'Ramp Unit' as set above.
Duration (Visible only for Time and Dwell segments)
Press scroll
until the display shows 'Duration". Press up
or down
to set a value.
Wait For (Visible only for Wait segments)
Press scroll
until the display shows 'Wait For'. Press up
or down
to select:
PrgIn1, PrgIn2, PrgIn1In2, PrgIn1orIn2, PVWaitIP.
GoBack to segment number (visible only for GoBack segments)
Press scroll
until the display shows 'GoBack Seg'. Press down
to select a segment
number to go back to.
GoBack Cycles (visible only for GoBack segments)
Press scroll
until the display shows 'GoBack Cycles'. Press up
or down
to set a
value.
Call Cycles (Visible only for call segments)
Press scroll
until the display shows 'Call Cycles'. Press up
or down
to set a
value.
End Type (Visible only for End segments)
Press scroll
until the display shows 'End Type'. Press up
or down
to select:
'Reset', 'Dwell' or 'SafeOp'.
3.8.6
Running a Program
The current program can be started from the home display by pressing RUN/HOLD or by
pressing page
once, then scroll
once (twice for P10 and P25), then press up
or
down
to change the status to 'Run'.
20
Summary of Contents for CARBOLITE GERO HTF 18/4
Page 7: ...Caution Double Pole Neutral Fusing 7 1 0 Symbols and Warnings ...
Page 37: ...Power Limit View 37 4 0 3508 Dual Loop Cascade ...
Page 59: ...59 8 0 Repairs and Replacements ...
Page 63: ...GR Y Green Yellow 63 10 0 Wiring Diagrams ...
Page 67: ...Notes Service Record Engineer Name Date Record of Work ...