![VERDER Carbolite Gero CDF 15/1b Installation, Operation & Maintenance Instructions Manual Download Page 14](http://html.mh-extra.com/html/verder/carbolite-gero-cdf-15-1b/carbolite-gero-cdf-15-1b_installation-operation-and-maintenance-instructions-manual_1003607014.webp)
CDF
14
MF56 – 1.05
8.0
F
USES
&
P
OWER
S
ETTINGS
8.1
Fuses
F1-F3: Refer to the circuit diagrams.
F1
Internal
supply fuses
Fitted if supply cable fitted.
Fitted on-board to some types of EMC filter.
16 Amps:
38mm x 10mm type F
F2
Auxiliary
circuit fuses
Fitted on-board to some types of EMC filter.
May be omitted up to 10 Amp/phase supply rating.
2 Amps glass type F
On board: 32mm x 6mm
Customer
fuses
Recommended if cable fitted.
See rating label for
amperage; see table below
for fuse rating.
Model
phases
Volts
Supply Fuse Rating
CDF 15/1b
1-phase
200-230
13A/ph