6
819.6247
Installation
Typical Installation
The installation shown in Fig. 3 is only a guide to help select
and install a pump; they are not actual system designs.
Typical installation includes (not supplied by VERDER):
For solenoid operation: four-way, 5-port, 2-position sole-
noid valve with 1/4-in. ports. Schrader Bellows
Part
No. C511ABB5 or equivalent.
PLC or timer. Consult your local industrial controls
distributor.
Caution
For solenoid operation, the pump must exhaust through the
solenoid. Failure to exhaust through solenoid could cause the
diaphragms to fail.
06504
Fig. 3
KEY
A
VERDER
AIR
VA 8
pump
B
Bleed-type master air valve
(required for pump)
C
Air line(s)
E
Master air valve (for accessories)
F
Air line filter
G
Muffler
H
Pump air regulator
J
Fluid drain valve
(required on fluid outlet side of pump)
L
Fluid suction line
N
Fluid supply hose
T
Bung adapter
U
4-way solenoid
Y
Ground wire (required)
See page 4 for installation instructions.
C
J
L
N
T
Y
A
U
Air line to Port A
Air line to Port B
Air line to inlet
Internal Air Valve Operated
Remote Solenoid Operated
E
H
B
G
F
Remote Solenoid View
Internal Air Valve View
(shown upright for clarity)
C
J
N
A
L
L
C