INSTRUCTIONS–PARTS LIST
Air-Operated
Diaphragm Pumps
819.0254
Rev. L
EN
Intended for use in accordance with the United States Flammable and Combustible Liquids
Code (NFPA 30) and the Automotive and Marine Service Station Code (NFPA 30A).
For professional use only.
VERDER VA 25
Evacuation and Transfer Pumps
120 psi; 0.84 MPa; 8.4 bar Maximum Fluid Working Pressure
120 psi; 0.84 MPa; 8.4 bar Maximum Air Input Pressure
Part No. 810.0780*
with TPE diaphragms and seats, acetal balls
Part No. 810.0930*
with TF diaphragms and balls, fluoroelastomer
seats
Patent No.
CN ZL94102643.4
FR 9408894
JA 3517270
US 5,368,452
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
This symbol on the nameplate means the
product is listed by Underwriters
Laboratories Inc. (UL Standard No. 79,
Standard for Power-Operated Pumps for
Petroleum Product Dispensing Systems).
II 2 GD
Ex h IIC 66°C...135°C Gb
Ex h IIIC T135°C Db
*
Model 810.0780
ATEX T-code rating is dependent on the temperature of the fluid
being pumped. Fluid temperature is limited by the materials of the
pump interior wetted parts. See Technical Data for the maximum
fluid operating temperature for your specific pump model.