8
819.4367
Installation
Changing the Orientation of the Fluid Inlet and
Outlet Ports
The pump is shipped with the fluid inlet (R) and outlet (S)
ports facing the same direction. See Fig. 4. To change the
orientation of the inlet and/or outlet port:
1.
Remove the screws (106 or 112) holding the inlet (102)
and/or outlet (103) manifold to the covers (101).
2.
Reverse the manifold and reattach. Install the
screws (106 or 112). Torque the manifold screws to
9–10 N
S
m. See Fig. 4. See Torque Sequence, page 30.
04155B
1
KEY
N
1/2 npt(f) air inlet port
P
Muffler; air exhaust port
is 3/4 npt(f)
R
1 in. fluid inlet port
S
1 in. fluid outlet port
101
Covers
102
Fluid inlet manifold
103
Fluid outlet manifold
106
Manifold screws
112
Manifold screws
N
P
R
S
1
Acetal Model Shown
103
102
101
112
106
Torque to 9 to 10 N
S
m. See Torque Sequence, page 30.
1
Fig. 4
Fluid Pressure Relief Valve
Some systems may require installation of a pressure relief
valve at the pump outlet to prevent overpressurization and
rupture of the pump or hose. See Fig. 5.
Thermal expansion of fluid in the outlet line can cause over-
pressurization. This can occur when using long fluid lines
exposed to sunlight or ambient heat, or when pumping from
a cool to a warm area (for example, from an underground
tank).
Overpressurization can also occur if the pump is being used
to feed fluid to a piston pump, and the intake valve of the
piston pump does not close, causing fluid to back up in the
outlet line.
Caution
Fig. 5
KEY
R
1 in. fluid inlet port
S
1 in. fluid outlet port
V
Pressure relief valve
Part No. 819.0159 (Stainless Steel)
1
2
Connect fluid inlet line here.
R
S
Connect fluid outlet line here.
1
2
3
Install valve between fluid inlet and outlet ports.
V
3
04228B
Summary of Contents for 810.0073
Page 24: ...24 819 4367 Notes...