36
Operation & maintenance manual, Discfilter HSF2200-1/2F PFC
7.5.2 Adjusting drive chain tension
Adjust the drive chain tension as follows:
1. Turn the main power switch to OFF (0) and lock with a padlock.
2. Loosen the four nuts (A) (see Figure 7.16).
3. Loosen the nut (B).
4. Adjust the tension of the chain using the screw (C).
5. Secure the screw (C) using the nut (B).
6. Tighten the four nuts (A).
7. Restart operation as described in section 5.1.
When the drive chain cannot be adjusted any further, the chain is worn out and must be replaced
(see section 7.5.3).
Figure 7.16 Adjusting drive chain tension.