background image

INSTRUCTION FOR INSTALLATION AND USE - VENUS - WOOD

MONTAGE- UND BEDIENUNGSANLEITUNG - VENUS - HOLTZ

M-DESIGN 

3

FIG. 1 

1. GENERAL

1.1 TRANSPORT AND INSTALLATION

• Transport the Luna in an upright position, or, in encumbering 

circumstances, at an angle of 45°.

• The handles for transportation purposes have been attached 

inside the slots provided on the sides of the Venus (see Fig.1)

1.2 FUEL

1.2.1 Wood

The quality of the wood is extremely important for the optimal 

functioning of the stove (output, clear glass, etc.).

Good quality wood is wood that has been dried under an aerated 

shelter for at least 2 years (+ 18% moisture content). Damp wood 

gives off less heat and dirties the stove and the chimney less.

You can also use briquettes (the effect is comparable with that of 

wood), and it is best to use them in combination with wood be

-

cause burning only briquettes makes the temperature too high.

Never fill the stove with wood because when the chimney draws 

too much, it can make the temperature too high. Damage as a 

result  of  excessive  temperature  is  not  under  guarantee.  2  to  3 

wooden logs are equal to 12 kW.

1.2.2 Forbidden fuel

The use of treated wood (painted, etc.) and all types of house

-

hold waste, which can disperse hazardous gases, is FORBIDDEN 

and CANCELS OUT ANY CLAIM ON THE GUARANTEE. The 

use of fluid fuel (petrol, etc.) is also forbidden.

1.ALLGEMEIN

1.1. TRANSPORT UND MONTAGE

•  Venus  sollte  stehend  transportiert  werden  oder  in  Aus

-

nahmefällen in einem Winkel von 45 °

•  Die Tragegriffe können in den hierfür vorgesehenen seitli

-

chen Schlitzen des Korpus befestiget werden.(sehe Fig. 1)

Das Öffnen und Schliessen der Türe :

Öffnen Sie die Türe langsam wenn das Feuer  brennt.  Das zu 

schnelle öffnen der Türe verursacht Rauchschwanden im Auf

-

stellraum.

TÜRE  SCHLIESSEN  :  den  Hebel  nach  oben  ziehen,  die  Türe 

gegen die Brennkamer drücken, danach den Hebel nach unten 

drücken bid eine komplette Sperre entsteht.

1.2 BRENNSTOFFE

1.2.1 Holz

Die Holzqualität ist sehr wichtig für eine optimale Verbrennung 

des  Kamins  (Leistung,  sauberes  Glas,  ...).  Gute  Qualität  hat 

Holz, das mindestens 2 Jahre trocken gelagert wurde (+/- 18% 

Feuchtigkeitsgehalt).  Feuchtes  Holz  erzeugt  weniger  Wärme 

und verschmutzt Kamin und Schornstein.

Sie können auch Holzbriketts verwenden (vergleichbar mit der 

Heizleistung  von  Holz). Am  Besten  aber  in  Kombination  mit 

Holz. Das ausschließliche Verbrennen von Briketts kann zu ei

-

ner zu hohen Temperatur führen. Der Feuerraum sollte nie ganz 

mit Holz bedeckt werden, da auch hier zu hohe Temperaturen 

entstehen können. (max 3-4 kg Holz/Std.)

Bei Schäden, die durch zu hohe Temperatur entstanden sind, 

besteht kein Garantieanspruch.

1.2.2 Nicht erlaubte Brennstoffe

Es ist verboten Holz mit Farbresten oder anderweitig behandel-

tem Holz sowie Abfall zu verbrennen. Die Verbrennung kann 

schädliche Gase verursachen und schließt die Gewährleistung 

aus.

Auch die Benutzung von flüssigen Brennstoffen (Benzin, ...) ist

verboten.

Summary of Contents for GREEN PLUS 630-730-700-850-1000-850D

Page 1: ...VENUS GREEN PLUS 630 730 700 850 1000 850D INSTRUCTION FOR INSTALLATION AND USE MONTAGE UND BEDIENUNGSANLEITUNG Passion for fire UK D 09 2011...

Page 2: ...PROVISO 14 4 3 DISCLAIMER 14 5 DRAWINGS 15 20 INHALT 1 ALLGEMEIN 3 1 1 TRANSPORT UND MONTAGE 3 1 2 BRENSTOFFE 3 1 2 1 Holz 1 2 2 Ungeeignete Brennstoffe 1 3 ANZ NDEN DES FEUERS 4 2 MONTAGEANLEITUNG 5...

Page 3: ...1 TRANSPORT UND MONTAGE Venus sollte stehend transportiert werden oder in Aus nahmef llen in einem Winkel von 45 Die Tragegriffe k nnen in den hierf r vorgesehenen seitli chen Schlitzen des Korpus bef...

Page 4: ...d in the fireplace This is like two normal pieces of wood Be carefull not to use palletwood this gives an enormous heat for con tinuous heating This can lead to fire hazard We are not responsible for...

Page 5: ...re Regelklappe und Abdeckplatte entfernen Brennkammer aus dem Au enmantel schieben Bild 4 Au enmantel montieren und Anschl sse installieren Ventilator installieren Option Bild 5 Wenn alle Montagearbe...

Page 6: ...rhalb des Knopfes Extras M Design entwickelt zurzeit einen neuen Induktionsdimmer mit dem der Ventilator fast ger uschlos dreht Nach 15 Minuten Brennzeit k nnen Sie den Ventilator starten Stellen Sie...

Page 7: ...RENNUNGSLUFTZUFUHR Jede Verbrennung braucht Luft Im Falle eines thermisch abges chlossenen Zimmers ist eine zus tzliche Luftzufuhr notwendig Auf jeden Fall sollte man vermeiden einen Unterdruck zu ver...

Page 8: ...Z M DESIGN 8 or oder Fig 9 Installation without fan CONVECTION DUCTING MUST BE INSTALLED Ohne Ventilator ANSCHLUSS FLEXTUBE VERPLICHTET 2 4 INSTALLATION WITHOUT FAN MONTAGE OHNE VENTILATOR Inlet grill...

Page 9: ...s er genug Bel ftung gibt so dass kein Vakuum Effekt entsteht Diese Installation ist nicht f r Passive H users empfohlen das gilt auch f r Installation mit Ventilator If no possibility to have externa...

Page 10: ...50 Inlet Grid convection air Zufurh Rost Konvektion Luft Inlet Grid convection air Zufuhr Rost convecktion luft Design Grid outlet with two connections Design Rost ausgang mit 2 Anschlussen 2 dm 4 dm...

Page 11: ...of direction The angle of the corner of these changes of direction may not be greater than 45 with the perpendicular The existing obstacles in the vicinity of the opening into the flue must be taken i...

Page 12: ...s green plus in sense of drought Regulierung Klappe Venus Door open T r offen 1 fig 2 unscrew 1 to have max closing Screw to let baffle plate inclinated like fig 2 max closing of baffle plate with doo...

Page 13: ...s burns better with its own ashes Cleaning the window Open the window Fig 11 We advise you to use M design s Bio Clean to clean the window which is available from your supplier It is one of the few pr...

Page 14: ...more than 12 kw Costs for packaging and transport All costs not pre arranged with M design Costs linked to the misuse and or abuse of the appliance 4 GARANTIE 4 1 DAUER UND EINSCHR NKUNGEN 8 Jahre Gar...

Page 15: ...N FOR INSTALLATION AND USE VENUS WOOD MONTAGE UND BEDIENUNGSANLEITUNG VENUS HOLTZ M DESIGN 15 418 40 516 195 739 679 605 545 674 205 230 720 150 200 100 min 73 max 370 VENUS 630 green plus Venus 630 G...

Page 16: ...N FOR INSTALLATION AND USE VENUS WOOD MONTAGE UND BEDIENUNGSANLEITUNG VENUS HOLTZ M DESIGN 16 418 40 210 516 774 705 645 839 779 205 230 820 250 150 min 73 max 370 100 VENUS 730 green plus Venus 730 G...

Page 17: ...INSTRUCTION FOR INSTALLATION AND USE VENUS WOOD MONTAGE UND BEDIENUNGSANLEITUNG VENUS HOLTZ M DESIGN 17 574 505 445 809 749 205 230 min 70 max 370 790 516 195 40 418 180 150 100 Venus 700 Green Plus...

Page 18: ...FOR INSTALLATION AND USE VENUS WOOD MONTAGE UND BEDIENUNGSANLEITUNG VENUS HOLTZ M DESIGN 18 624 5 555 495 899 959 205 230 516 195 40 200 150 418 940 min 73 max 370 100 VENUS 850 green plus Venus 850...

Page 19: ...FOR INSTALLATION AND USE VENUS WOOD MONTAGE UND BEDIENUNGSANLEITUNG VENUS HOLTZ M DESIGN 19 516 40 210 1109 1049 605 674 545 205 230 250 418 150 1090 min 73 max 370 100 VENUS 1000 green plus Venus 100...

Page 20: ...NSTRUCTION FOR INSTALLATION AND USE VENUS WOOD MONTAGE UND BEDIENUNGSANLEITUNG VENUS HOLTZ M DESIGN 20 Venus 850D Green Plus FAN OPTION NOT AVAILABLE FOR VENUS 850 D VENTILATOR NICHT M GLICH F R 850 D...

Reviews: