background image

VUT 180 P5 

VUE 180 P5 

VUT 180 P5 EC 

VUE 180 P5 EC 

VUT 180 P5B EC 

VUE 180 P5B EC

Air handling unit

USER’S MANUAL

Summary of Contents for VUE 180 P5 EC

Page 1: ...VUT 180 P5 VUE 180 P5 VUT 180 P5 EC VUE 180 P5 EC VUT 180 P5B EC VUE 180 P5B EC Air handling unit USER S MANUAL...

Page 2: ...e in order to incorporate the latest technological developments No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means in any information...

Page 3: ...ldren to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit...

Page 4: ...substances toxic substances dust pathogenic germs The relative humidity of the transported air at a temperature of 20 C should not exceed 80 DELIVERY SET NAME NUMBER Air handling unit 1 pc User s manu...

Page 5: ...anual TECHNICAL DATA MODEL VUT 180 P5 B VUE 180 P5 B VUT 180 P5 VUE 180 P5 Voltage V 50 60 Hz 1 220 240 Maximum fan power W 87 117 Maximum unit current without a heater A 0 71 0 54 Maximum air flow m3...

Page 6: ...at exchanger Bypass damper Supply filter F7 Supply filter G4 The service side of the unit is equipped with detachable plates fixed by screws for filter cleaning and replacement operations The control...

Page 7: ...to the cold fresh air The air flows are fully separated while flowing through the heat exchanger Heat recovery minimizes heat losses which reduces the cost of space heating in the cold season SUPPLY A...

Page 8: ...t air duct length equal to 1 air duct diameter on intake side equal to 3 air duct diameters on outlet side If the air ducts are too short or not connected protect the unit parts from ingress of foreig...

Page 9: ...Fasteners for unit mounting should be selected by the Customer Service technician Unscrew the thumbscrews on the unit before attaching it to the mounting brackets Set the unit thumbscrews into the ma...

Page 10: ...pes is in the cover of the unit Remove the plug from the hole open the service panel and install the drain pipe from the delivery set into the hole The drain pipes should be installed only in the hole...

Page 11: ...ach drain pipe is connected to a different U trap min 3 Drain hose U trap Sewage system Drain pipe The condensate drainage system is designed for normal operation in premises with air temperatures abo...

Page 12: ...Y THE POWER CABLE OF THE UNIT IN CLOSE PROXIMITY AND PARALLEL TO THE CONTROL PANEL CABLE DO NOT COIL THE CONTROL PANEL CABLE WHILE LAYING ITS OUT External control units wiring diagram for units with a...

Page 13: ...3 230 V 50 60 Hz Designation Name Wire P1 Control panel 4 x 0 75 mm2 Designation Name Wire P1 Control panel 6 x 0 6 mm2 External control units wiring diagram for units with an A21 control panel GND 24...

Page 14: ...To clean or replace the filters remove the detachable plates located on the service side of the unit After cleaning install the filters and the detachable plates in the reverse order 2 Heat exchanger...

Page 15: ...ctly otherwise troubleshoot the connection error The motor is jammed the impeller blades are clogged Turn the unit off Troubleshoot the motor jam and the impeller clogging Clean the blades Restart the...

Page 16: ...table hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in...

Page 17: ...ing cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch...

Page 18: ...18 www ventilation system com VUT VUE 180 P5 B EC...

Page 19: ...ual The warranty terms are acknowledged and accepted Customer s Signature The VUT VUE 180 P5___ EC A____ unit has been connected to power mains pursuant to the requirements stated in the present user...

Page 20: ...V170EN 03...