Problem

Possible reasons

Troubleshooting

The fan does not start.

No power supply.

Make sure the power supply line is connected 

correctly, otherwise troubleshoot a connection error.

Noise, vibration.

The fan impeller is soiled.

Clean the impellers.

The fan or casing screw connection is loose.

Tighten the screw connection of the casing against 

stop.

STORAGE AND TRANSPORTATION REGULATIONS

•  Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range 

from +5 ˚C  to +40 ˚C  and relative humidity up to 70 %.

•  Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and sealing 

deformation.

•  Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit.
•  Follow the handling requirements applicable for the particular type of cargo.
•  The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and 

mechanical damage. The unit must be transported only in the working position.

•  Avoid sharp blows, scratches, or rough handling during loading and unloading.
•  Prior to the initial power-up after transportation at low temperatures, allow the unit to warm up at operating temperature for at least 

3-4 hours.

TROUBLESHOOTING

Summary of Contents for VKV EC

Page 1: ...USER S MANUAL VKV EC VKH EC Centrifugal roof fan...

Page 2: ...cal training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the cou...

Page 3: ...age the impeller blades While mounting the unit avoid compression of the casing Deformation of the casing may result in motor jam and excessive noise Misuse of the unit and any unauthorised modificati...

Page 4: ...the fixed wiring system in accordance with the wiring rules for design of electrical units and has a contact separation in all poles that allows for full disconnection under overvoltage category III c...

Page 5: ...f fans in metal casing are designed for ventilation systems in industrial premises as well as pools apartment buildings offices hospitals restaurants and other premises heated during the winter season...

Page 6: ...M6 263 270 451 450 330 16 VKH 355 EC 438 11 M8 322 361 625 620 450 27 VKH 400 EC 438 11 M8 384 422 625 620 450 27 VKH 450 EC 438 11 M8 420 459 710 700 535 46 VKH 500 EC 445 11 M8 467 506 710 700 535...

Page 7: ...gress of water and snow into the ventilation duct it is possible to install a fan on the mounting frame The fan is connected to the ventilation duct by means of a counter flange which is attached dire...

Page 8: ...ifications section according to the wiring diagram The unit must be connected to power mains using insulated electric conductors cables wires The actual wire cross section selection must be based on t...

Page 9: ...T GND Tacho A QF 1 L1 2 L2 3 L3 4 1 2 3 4 X1 X2 ND T acho 10 0 V CRT GND Tacho A QF 0 10V 400 V 50 60 Hz 1 L1 2 L2 3 L3 4 1 X1 X2 PE L3 L2 L1 10V 10V A QF 1 L1 2 L2 3 L3 4 1 X1 X2 PE L3 L2 L1 10V 10V...

Page 10: ...se a soft dry cloth brush or compressed air to remove dust Carry out wet cleaning using warm water and a mild household detergent Protect the electric motor against liquid ingress Do not immerse the u...

Page 11: ...11 www ventilation system com VKV 190 EC VKV 225 EC VKV 250 EC VKV 280 EC VKV 310 EC VKV 355 EC with a hinged cover and a motor...

Page 12: ...humidity up to 70 Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion insulation and sealing deformation Use suitable hoist machinery for handling and stor...

Page 13: ...ler for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including s...

Page 14: ...IFICATE The VK__ EC__________________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installati...

Page 15: ...15 www ventilation system com...

Page 16: ...V204 1EN 02...

Reviews: