MOUNTING 

The fan is designed for horizontal or vertical installation on the floor, on the wall or on the ceiling (Fig. 1). The 
fan can be installed independently or as part of a set with parallel or in-series connection (Fig. 2).
To be installed on the intake spigot side: 
• 1 m long air duct in case of horizontal fan installation 
• ventilation hood in case of vertical fan installation
The exhaust spigot must always be connected to the air duct. 
The fan mounting steps are shown in Fig. 3–10 and 25-30.
The wiring diagrams are shown in Fig. 11-24.

Terminal designations:

L1

: minimum speed terminal 

L2

: maximum speed terminal 

QF

: automatic circuit breaker

S

: external speed switch 

ST

: external switch (for example, light switch)

X

: input terminal block

QF

S

S/ST

Automatic circuit breaker 

designation

Automatic 

circuit breaker

External switch designation

External switch

Summary of Contents for VENTS TT Series

Page 1: ...CENTRIFUGAL INLINE FAN USER S MANUAL www ventilation system com TT EN ...

Page 2: ...NTENTS Delivery set 6 Brief description 6 Fan modifications 6 Operation guidelines 7 Designation key 8 Mounting 9 Control logic 10 Maintenance 12 Transportation and storage rules 12 Manufacturer s warranty 13 ...

Page 3: ...nance staff must have theoretical and practical training in the field of ventilation systems and should be able to perform works in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country The information in this user s manual is correct at the time of the document s preparation The Company reserves the right to modify the techni...

Page 4: ... QF automatic circuit breaker integrated into the fixed wiring system The gap between the circuit breaker contacts on all poles must be not less than 3 mm Check the unit for any visible damages of the impeller and the casing before starting installation The casing internals must be free of any foreign objects that can damage the impeller blades While mounting the unit avoid compression of the casi...

Page 5: ... containing spirits gasoline insecticides etc Do not close or block the intake or extract vents in order to ensure the efficient air flow Do not sit on the unit and do not put objects on it The unit is allowed to be used by children aged from 8 years old and above and persons with reduced physical sensory or mental capabilities or no experience and knowledge provided that they have been given supe...

Page 6: ...S TT XXX basic model VENTS TT XXX S model with high powered motor VENTS TT XXX V model with integrated speed switch VENTS TT XXX RV model with integrated speed switch and power cable with plug Fig 32 VENTS TT XXX T model with turn off delay timer adjustable from 2 to 30 minutes Fig 31 VENTS TT XXX U U1 model with a speed controller with electronic thermostat integrated temperature sensor and power...

Page 7: ...ion The arrow on the fan casing must match the air direction in the system Ingress protection rating against access to hazardous parts and water ingress is IPX4 The fan is rated for operation at the ambient air temperature from 1 C up to 45 C The transported air temperature must not exceed 60 C The unit is rated as a Class II electrical appliance ...

Page 8: ...erature based control unit external temperature sensor 0 4 m power cable U1 electronic timer based control unit integrated duct temperature sensor 0 4 m power cable U1n electronic timer based control unit external temperature sensor 0 4 m power cable P built in speed controller and 0 4 power cable R 0 4 power cable V switch High powered motor Spigot diameter mm Inline fan ...

Page 9: ...n ventilation hood in case of vertical fan installation The exhaust spigot must always be connected to the air duct The fan mounting steps are shown in Fig 3 10 and 25 30 The wiring diagrams are shown in Fig 11 24 Terminal designations L1 minimum speed terminal L2 maximum speed terminal QF automatic circuit breaker S external speed switch ST external switch for example light switch X input termina...

Page 10: ...nt of the fan parameters Use exclusively the delivered plastic screwdriver to adjust the turn off delay time Do not use a metal screwdriver knife etc for adjustment operations not to damage the circuit board The TT XXX U U1 fan is equipped with an electronic TSC control unit speed controller with electronic thermostat for automatic speed control air flow control depending on the air temperature Fi...

Page 11: ... is used for exact air temperature control The speed switches are more frequent as compared to the temperature based functioning logic but one speed interval continues at least 5 minutes As the indoor air temperature exceeds the set point the fan switches to the maximum speed As the room air temperature drops down below the temperature set point the timer starts 5 minutes countdown and then the fa...

Page 12: ...0 Storage environment must not contain aggressive vapours and chemical mixtures provoking corrosion insulation and sealing deformation Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided ...

Page 13: ...es work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component The warranty repair does not include routine technical maintenance unit installation dismantling unit setup To benefit from warran...

Page 14: ... any persons without the manufacturer s authorization Expiration of the unit warranty period Violation of the unit transportation regulations by the user Violation of the unit storage regulations by the user Wrongful actions against the unit committed by third parties Unit breakdown due to circumstances of insuperable force fire flood earthquake war hostilities of any kind blockades Missing seals ...

Page 15: ...15 EN min 1 m 1 2 ...

Page 16: ...16 EN QF 3 4 5 6 ...

Page 17: ...17 EN 7 8 9 10 ...

Page 18: ... EN MAX MIN MAX MIN MAX MIN MAX MIN N L2 N L QF X N L1 N L QF X QF N L1 L2 S N L X L2 L L1 N X N L1 N L QF X N L2 N L QF X L2 L L1 N X QF N L1 L2 S N L X 11 12 13 14 15 16 17 18 TT 100 125 TT 125S 150 160 ...

Page 19: ...X L2 N L ST QF N L LT X N L ST QF N L LT L1 X S N L ST QF N L LT L1 X N L ST QF N L LT L2 X 19 20 21 22 Terminal box for 5 contacts Terminal box for 5 contacts Terminal box for 5 contacts Terminal box for 4 contacts Terminal box for 4 contacts Terminal box for 4 contacts TT XXX T ...

Page 20: ...20 EN MAX L2 L L1 N X N L2 X N L QF TT 250 TT 315 23 24 ...

Page 21: ...21 EN 25 26 27 28 29 30 ...

Page 22: ...22 EN MIN MAX STOP X 30 min 2 min 31 32 ...

Page 23: ...23 EN 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 m in m a x tC 3 0 C 2 0 C m in m a x 33 34 TT U U1 TT Un U1n Temperature control knob Speed control knob Speed control knob ...

Page 24: ...24 EN 35 36 37 38 ...

Page 25: ...25 EN ﻮ و 39 40 41 ...

Page 26: ...26 EN ...

Page 27: ...27 EN Approval mark Manufacturing date Sold name and stamp of the seller Sales date ...

Page 28: ...V10EN 10 Certificate of acceptance The fan is recognized as serviceable TT 100 V 1 n 125 RV 125C T 150 U 160 P 250 315 ...

Reviews: