VCUN 500х204-11,0-4D 

1210 818 487 341 372 855 634 335 466 510 835 375 396 323 435 470 470 401 12 15

175

VCUN 500х204-15,0-4D 

1210 818 532 341 372 915 634 335 466 510 835 375 396 323 435 470 470 401 12 15

185

VCUN 500х204-18,5-4D 

1215 818 553 341 372 945 639 335 466 510 835 375 396 323 435 470 470 401 12 15

222

VCUN 500х204-22,0-4D 

1215 818 591 341 372 983 639 335 504 554 920 400 396 323 435 470 470 401 12 18

255

VCUN 120х62-0,37-2D 
(400V/60Hz)

329 211 192 82 103 306 175 93 174 191 268 120 93 86 123 145 145 135 8

7

7.5

VCUN 120х62-0,37-2E 
(230V/60Hz)

329 211 220 82 103 335 175 93 174 191 268 120 93 86 123 145 145 135 8

7

9.3

VCUN 146х62-0,75-2D 
(400V/60Hz)

385 249 220 100 118 345 203 102 174 191 293 135 114 96 141 165 165 149 8

7

10.2

VCUN 146х62-0,75-2E 
(230V/60Hz)

385 249 237 100 118 378 203 102 199 221 345 150 114 96 141 165 165 149 8

9

15

VCUN 160х74-0,18-4D 
(400V/60Hz)

414 275 192 109 132 335 215 120 179 201 305 135 125 112 156 180 180 166 8

9

7.2

VCUN 160х74-1,1-2D 
(400V/60Hz)

414 275 237 109 132 379 215 120 199 221 345 150 125 112 156 180 180 166 8

9

15.5

VCUN 160х74-1,1-2E 
(230V/60Hz)

414 275 237 109 132 379 215 120 199 221 345 150 125 112 156 180 180 166 8

9

16

VCUN 180х74-0,37-4D 
(400V/60Hz)

455 304 220 123 143 366 235 123 199 221 345 150 141 116 171 195 195 170 8

9

9.5

VCUN 180х74-2,2-2D 
(400V/60Hz)

455 304 280 123 143 433 235 123 220 246 400 175 141 116 171 195 195 170 8

9

27

VCUN 180х74-0,37-4E 
(230V/60Hz)

455 304 220 123 143 366 235 123 199 221 345 150 141 116 171 195 195 170 8

9

9.5

VCUN 180х74-2,2-2E 
(230V/60Hz)

455 304 280 123 143 433 235 123 220 26 400 175 141 116 171 195 195 170 8

11

27.5

VCUN 200х92-0,75-4D 
(400V/60Hz)

507 334 236 137 155 405 265 146 220 246 400 175 157 138 187 211 211 192 8

11

18

VCUN 200х92-2,2-2D 
(400V/60Hz)

507 334 279 137 155 448 265 146 220 246 400 175 157 138 187 211 211 192 8

11

28.5

VCUN 200х92-3,0-2D 
(400V/60Hz)

507 334 279 137 155 448 265 146 220 246 400 175 157 138 187 211 211 192 8

11

30

VCUN 200х92-0,75-4E 
(230V/60Hz)

507 334 236 137 155 405 265 146 220 246 400 175 157 138 187 211 211 192 8

11

19

VCUN 200х92-2,2-2E 
(230V/60Hz)

507 334 279 137 155 448 265 146 220 246 400 175 157 138 187 211 211 192 8

11

30.5

VCUN 225х102-0,75-4D 
(400V/60Hz)

598 376 236 154 175 428 324 165 254 290 446 200 177 157 211 241 241 221 8

13

20.5

VCUN 225х102-1,1-4D 
(400V/60Hz)

598 376 236 154 175 428 324 165 254 290 446 200 177 157 211 241 241 221 8

13

21

VCUN 225х102-1,5-4D 
(400V/60Hz)

598 376 279 154 175 472 324 165 254 290 446 200 177 157 211 241 241 221 8

13

30

VCUN 225х102-1,1-4E 
(230V/60Hz)

598 376 279 154 175 472 324 165 254 290 446 200 177 157 211 241 241 221 8

13

30.5

VCUN 250х102-0,55-6D 
(400V/60Hz)

625 413 236 171 189 439 324 175 254 290 446 200 197 168 231 261 261 232 8

13

22

VCUN 250х102-1,5-4D 
(400V/60Hz)

625 413 279 171 189 482 324 175 254 290 446 200 197 168 231 261 261 232 8

13

32

VCUN 250х102-1,5-4E 
(230V/60Hz)

625 413 279 171 189 482 324 175 254 290 446 200 197 168 231 261 261 232 8

13

32

VCUN 280х102-0,75-6D 
(400V/60Hz)

698 463 236 191 213 444 364 180 254 290 446 200 220 171 255 285 285 237 10 13

23.5

VCUN 280х102-2,2-4D 
(400V/60Hz)

698 463 334 191 213 542 364 180 314 350 446 200 220 171 255 285 285 237 10 13

41.5

Summary of Contents for VCUN

Page 1: ...VCUN USER S MANUAL Centrifugal fan in a scroll casing...

Page 2: ...field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country CONTENTS Safet...

Page 3: ...Do not put any foreign objects on the power cable Do not lay the power cable of the unit in close proximity to heating equipment Do not use damaged equipment or cables when connecting the unit to pow...

Page 4: ...ifugal fans in a scroll casing are designed for supply and exhaust ventilation of domestic public and industrial premises The unit is rated for continuous operation Transported air must not contain an...

Page 5: ...Hz 400 60 Hz supply voltage 400 V power frequency 60 Hz Options _ model for temperate climate T model for tropical climate M model for marine climate SW sea air resistant motor Rotation angle of the c...

Page 6: ...RS ON THE LABEL AND IN THE ABSENCE OF THERMAL PROTECTION OF THE MOTOR TECHNICAL DATA The fan is designed for ambient temperature ranging from 1 C up to 40 C and relative humidity up to 80 The fan desi...

Page 7: ...35 125 112 156 180 180 166 8 9 8 VCUN 180 74 0 18 4D 455 304 192 123 143 339 235 123 199 221 345 150 141 116 171 195 195 170 8 9 8 VCUN 180 74 1 1 2D 455 304 237 123 143 383 235 123 199 221 345 150 14...

Page 8: ...2 231 314 350 557 240 248 221 288 323 323 297 12 13 58 VCUN 355 143 1 1 6D 882 579 279 242 262 550 462 239 314 350 557 240 280 228 320 355 355 304 12 13 48 VCUN 355 143 1 5 6D 882 579 315 242 262 587...

Page 9: ...0 141 116 171 195 195 170 8 9 9 5 VCUN 180 74 2 2 2E 230V 60Hz 455 304 280 123 143 433 235 123 220 26 400 175 141 116 171 195 195 170 8 11 27 5 VCUN 200 92 0 75 4D 400V 60Hz 507 334 236 137 155 405 26...

Page 10: ...2 239 314 350 557 240 280 228 320 355 355 304 12 13 63 VCUN 355 143 5 5 4D 400V 60Hz 882 579 408 242 262 680 462 239 314 350 557 240 280 228 320 355 355 304 12 13 65 VCUN 355 143 7 5 4D 400V 60Hz 882...

Page 11: ...o the drive shaft A bracket for mounting the fan is attached to the bottom of the electric motor VCUN fans are available in right hand and left hand versions In the first case the impeller rotates clo...

Page 12: ...the motor windings and between each winding and the motor frame Follow the safety regulations during the make ready procedures and fan operation VCUN fan installation sequence Make sure that the fan i...

Page 13: ...nt of the product see technical data VCUN fan connection sequence Check that there is no voltage on the supply cable Remove the cover from the terminal box located on the motor casing Pull the power s...

Page 14: ...checklist Service the fan regularly to ensure reliable safe and efficient operation General maintenance includes Daily technical maintenance DTM Technical maintenance TM 1 after 1000 hours Current re...

Page 15: ...NSPORTATION REGULATIONS Store the unit in the manufacturer s original packaging box in a dry closed ventilated premise with temperature range from 5 C to 40 C and relative humidity up to 70 Storage en...

Page 16: ...antling unit setup To benefit from warranty repair the user must provide the unit the user s manual with the purchase date stamp and the payment paperwork certifying the purchase The unit model must c...

Page 17: ...TIFICATE The VCUN ___________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s...

Page 18: ...18 VCUN www ventilation system com...

Page 19: ...19 www ventilation system com...

Page 20: ...V16 1EN 01...

Reviews: