Vents PU JK 01 User Manual Download Page 6

6

PU JK

PU JK

7. Service Menu.

To access the service menu enter the User Menu by pressing the 

 button and select 

the service menu access mode. 

While in the service menu access mode the 

 indicator is blinking. 

Then press the 

 

button. 

The service menu provides access to a number of ventilation unit parameters such as:

  Date and Time Setup. 

  Unit Parameters Setup. 

  Timer Setup. 

  Temperature Indication Correction. 

  Reset to Factory Settings. 

  Motor Hour Reset. 

  Humidity Feedback Control Activation. 

8. Date and Time Setup.

To set the current date and time enter the service menu and use the 

 button to 

select the date and time setup mode. 

While in the date and time setup mode the 

 and   indicators on the control 

panel display are blinking. 

Then press the 

 button to enter date and time setup mode. 

Use the 

 button to select the parameter to be edited and set the desired value by 

means of the 

 and 

 buttons. 

The date and time parameters appear in the following order: 

  Minutes.

  Hours.

  Day of the Week.

  Date. 

  Month. 

6. Timer On / Off 

The timer is used to switch the fans to the speed defi ned in the service menu («Timer 

Mode Air Flow» parameter) with an automatic return to the previous speed after a set 

time period. The timer operation period is defi ned via the service menu. 

To control the timer status use the 

 button to enter the user menu. 

Select timer control mode. While in the timer control mode the 

 indicator 

is blinking.

Use the 

 and 

 buttons to set the timer status: 

 — The timer is On. 

 — The timer is Off . 

To control the timer via the remote control use the 

 button.

9. Ventilation Unit Parameters Setup.

To set the ventilation unit parameters enter the service menu and use the 

 button 

to select the date and time setup mode. 

While in the date and time setup mode the 

 indicator and the 

 ventilation 

unit parameters setup indicator on the control panel display are blinking. 

Then press the 

 

button to enter the ventilation unit parameters setup mode. 

 

Summary of Contents for PU JK 01

Page 1: ...USER S MANUAL PU JK 01 LCD Control Panel...

Page 2: ...to every installation or repair operation The control panel must not be operated outside the temperature range stated in the user s manual or in aggressive or explosive environments Do not position an...

Page 3: ...included in the delivery PARAMETER VALUE Ambient Temperature C From 5 to 40 Relative Humidity From 5 to 80 no condensation Recommended cable cross section mm2 0 22 0 25 Material Plastic Dimensions W...

Page 4: ...r lights up when the bypass opens Timer status the indicator lights up when the timer is activated the indicator glows when the timer is off Heater status the indicator glows while the heater is on 1...

Page 5: ...buttons to set the heater status the indicator is blinking fast the heater is off the indicator is blinking slowly the heater is on From the remote control press the button to switch the heater on pr...

Page 6: ...e by means of the and buttons The date and time parameters appear in the following order Minutes Hours Day of the Week Date Month 6 Timer On Off The timer is used to switch the fans to the speed defin...

Page 7: ...on to select the reset to factory settings mode While in the reset to factory settings mode the and the indicators on the control panel display are blinking Then press the button to enter the Reset to...

Page 8: ...urn heat medium temperature sensor malfunction 04 Heater freeze temperature sensor malfunction 05 Duct temperature sensor malfunction 06 Duct humidity sensor malfunction 07 Supply fan malfunction 08 E...

Page 9: ...ature 10 30 User defined Temperature in the Standby Mode 20 29 Air Flow at Low Speed in Air Extract Mode 0 99 Air flow in the exhaust air duct at low speed defined as a percentage of the maximum unit...

Page 10: ...V55 5EN 02 1...