•  Disconnect the unit from power supply prior to any connection, servicing and repair operations.
•  Prior to installing the fan make sure the casing has no visible damages and check the integrity of power supply wires. The fan casing 

must not contain any foreign objects which can damage the impeller blades. 

•  Make sure the impeller rotates freely without touching the flange and the casing.
•  The fan shall be installed in the air duct with the same diameter.
•  Mount the fan in such a way that the arrow on the fan casing matches the air flow direction in the system.
•  Install flexible connectors on both sides of the fan (purchased separately).
•  Ensure a direct air duct section of at least one air duct diameter long on the inlet side and at least three air duct diameters long on 

the outlet side.

•  The fan is not a ready to use unit and requires connection to the air ducts.
•  Install the fan securely while ensuring free access for maintenance operations.
•  The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand 

4 times the weight of the ceiling fan.

•  When mounting the fan outdoors, protect it against weather impact and water ingress, for example, by mounting a hood over the fan.
•  Take steps to prevent back flow of gases from devices using gas and open flames.

MOUNTING SEQUENCE

 

1. Mark the holes for mounting the fan.

2. Drill the holes according to the markings. 3. Mount the fan on the mounting bracket.

Connect air ducts to the fan.

READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT.

WHILE INSTALLING THE UNIT ENSURE CONVENIENT ACCESS FOR SUBSEQUENT 

MAINTENANCE AND REPAIR. 

THE UNIT MUST BE MOUNTED ON A PLANE SURFACE.

MOUNTING OF THE UNIT TO AN UNEVEN SURFACE CAN LEAD TO THE UNIT CASING 

DISTORTION AND OPERATION DISTURBANCE.

MOUNTING AND SET-UP

Summary of Contents for KSA 200-4E

Page 1: ...KSA Centrifugal fan in sound insulated casing USER S MANUAL...

Page 2: ...country CONTENTS SAFETY REQUIREMENTS All user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must be...

Page 3: ...ars and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in...

Page 4: ...the safety suspension system device shall be performed by the manufacturer its service agent or suitably qualified persons Fixing means for attachment to the ceiling such as hooks or other devices sh...

Page 5: ...ller with an electronic thermostat and a temperature sensor built into the duct Algorithm for turning on and off by temperature U2n is a speed controller with an electronic thermostat and an external...

Page 6: ...350 295 344 183 231 6 3 KSA 160 2E 159 350 295 343 183 231 6 3 KSA 200 4E 199 436 361 409 233 282 8 3 MAIN TECHNICAL PARAMETERS OF THE FANS KSA 100 2E KSA 125 2E KSA 150 2E KSA 160 2E KSA 200 4E Volta...

Page 7: ...fan cover It lights up when the air temperature exceeds the set value To set the thermostat threshold turn the temperature control knob clockwise to increase the value and counter clockwise to decreas...

Page 8: ...The fan is not a ready to use unit and requires connection to the air ducts Install the fan securely while ensuring free access for maintenance operations The fixing means for attachment to the ceili...

Page 9: ...he external automatic circuit breaker must ensure free access for quick power off of the unit The automatic circuit breaker nominal current must exceed the ventilator current consumption It is recomme...

Page 10: ...wet cleaning using warm water and a mild household detergent Avoid water splashes on the unit Do not immerse the unit in water Do not use aggressive solvents or sharp objects as they may damage the i...

Page 11: ...f transport provided proper protection against precipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blows scratches or rough handling during loadin...

Page 12: ...eller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including...

Page 13: ...TE The _____________________________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Techni...

Page 14: ...14 KSA www ventilation system com...

Page 15: ...15 www ventilation system com...

Page 16: ...V42EN 08...

Reviews: