This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the HBF unit and all its 
modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to 
work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.

Safety requirements ..................................................................................................................................................................... 3
Purpose ................................................................................................................................................................................................ 5
Delivery set ........................................................................................................................................................................................ 5
Designation key .............................................................................................................................................................................. 5
Technical data .................................................................................................................................................................................. 6
Design and functioning ............................................................................................................................................................ 7
Mounting and set-up .................................................................................................................................................................. 8
Connection to power mains .................................................................................................................................................. 10
Electronics operation algorithm  ......................................................................................................................................... 11
Technical maintenance .............................................................................................................................................................. 12
Storage and transportation regulations .......................................................................................................................... 12
Manufacturer’s warranty ........................................................................................................................................................... 13
Certificate of acceptance .......................................................................................................................................................... 15
Seller information .......................................................................................................................................................................... 15
Installation certificate .................................................................................................................................................................. 15
Warranty card ................................................................................................................................................................................... 15

Summary of Contents for HBF 250

Page 1: ...HBF Centrifugal ceiling extract fan USER S MANUAL...

Page 2: ...n the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country Safety re...

Page 3: ...r must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in a hazardous or explosive environment containing spirits gasoline insecticides etc Do...

Page 4: ...lows for full disconnection under overvoltage category III conditions If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to...

Page 5: ...re Centrifugal ceiling extract fan 1 pc 1 pc Decorative grille 1 pc User s manual 1 pc 1 pc Packing box 1 pc 1 pc For a fan without a decorative panel you need to purchase a decorative panel designed...

Page 6: ...appliance Ingress protection rating against access to hazardous parts and water ingress is IPX4 The unit design is constantly being improved thus some models may be slightly different from those desc...

Page 7: ...to power mains and to electronics board if available A single phase electric motor with a centrifugal impeller with forward curved blades is fastened inside of the casing Depending on the model the fa...

Page 8: ...the ceiling surface using removable rotary clamping brackets on the fan casing The fan installation location must comply with local building codes for this type of product Check the fan for mechanical...

Page 9: ...ws on the rocking levers thereby increasing the gap between the casing and the lever 4 The spigot and the air duct are installed on the fan 5 The fan assembly is inserted into the ceiling opening from...

Page 10: ...cess for quick power off of the unit WIRING DIAGRAM OF THE FAN HBF HBFT HBFTH 8 mm max L QF L N N S N QF L N L S1 S N QF L N L S1 TERMINAL DESIGNATIONS ON THE WIRING DIAGRAM L phase N neutral S1 switc...

Page 11: ...evel drops down the fan keeps operating for a set turn off delay time period adjustable from 0 to 30 minutes and then turns off The fan delivery set includes a specially designed plastic screwdriver f...

Page 12: ...temperature range from 5 C to 40 C and relative humidity up to 70 Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion insulation and sealing deformation Us...

Page 13: ...ler for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including s...

Page 14: ...14 HBF www ventilation system com...