Vents 100 Ace User Manual Download Page 17

17

EN

13.

S

N

QF

L

N

L

S1

Fan does not run

Contact of S1 switch or

 pull cord switch is

 CLOSED

Switch is OFF during countdown 

of turn-on delay timer

Fan runs

Contact of S1 switch or 

pull cord switch is 

OPENED

Activation of turn-off

 delay timer (2-30 minutes)

Yes

No

100/125 Ace T1                                                              

Activation of turn-off 

delay timer (0-2 minutes)

Summary of Contents for 100 Ace

Page 1: ...AXIAL FAN User s manual www ventilation system com Ace EN...

Page 2: ...licable in the territory of the country The information in this user s manual is correct at the time of the document s preparation The Company reserves the right to modify the technical characteristic...

Page 3: ...user s manual should be carefully read before beginning works Single phase power mains must comply with the acting local electrical norms and standards Fixed electrical wiring must be equipped with an...

Page 4: ...the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to...

Page 5: ...t is allowed to be used by children aged from 8 years old and above and persons with reduced physical sensory or mental capabilities or no experience and knowledge provided that they have been given s...

Page 6: ...fan is off The fan is designed for connection to 100 and 125 mm air ducts CAUTION The decorative front panel is available separately OPERATION GUIDELINES The fan is rated for connection to 220 240 V 5...

Page 7: ...speed motor Duo two speed motor L motor with ball bearings Options S pull cord switch turn off delay timer 1 turn on and turn off delay timer VT turn on turn off delay timer and pull cord switch humid...

Page 8: ...et by the turn off delay timer within the range from 2 to 30 minutes The fan with the Duo T1 timer runs at 1st speed When the control voltage is applied to the S input the turn on delay timer is activ...

Page 9: ...itch the fan switches to 2nd speed with a time delay of 45 s After the switch is turned off the fan will continue to work at the 2nd speed for the time set by the turn off delay timer from 2 to 30 min...

Page 10: ...accumulate on the surfaces Fig 18 21 use a soft cloth and a brush soaked in a mild detergent solution Avoid spilling liquid on the electrical components Wipe the cleaned surfaces dry DO NOT USE A META...

Page 11: ...be transported only in the working position Avoid sharp blows scratches or rough handling during loading and unloading Prior to the initial power up after transportation at low temperatures allow the...

Page 12: ...air includes work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replace...

Page 13: ...ower mains with a voltage different from the one stated in the user s manual Unit breakdown due to voltage surges in power mains Discretionary repair of the unit by the user Unit repair by any persons...

Page 14: ...14 EN A B L D 1 2 D mm A mm B mm L mm 100 Ace 99 151 128 115 125 Ace 124 180 158 122...

Page 15: ...15 EN QF L N 3 4 5 6 7 8 9 10 11 CAUTION The decorative front panel is available separately...

Page 16: ...L N L S1 Fan does not run Contact of S1 switch or pull cord switch is CLOSED Fan runs Contact of S1 switch or pull cord switch is OPENED Activation of turn off delay timer 2 30 minutes 100 125 Ace 100...

Page 17: ...or pull cord switch is CLOSED Switch is OFF during countdown of turn on delay timer Fan runs Contact of S1 switch or pull cord switch is OPENED Activation of turn off delay timer 2 30 minutes Yes No...

Page 18: ...point No Yes Humidity is below set point Activation of turn off delay timer 2 30 minutes Contact of S1 switch or pull cord switch is CLOSED Fan runs Contact of S1 switch or pull cord switch is OPENED...

Page 19: ...L S1 Fan runs at speed 1 Contact of S1 switch is CLOSED Activation of turn on delay timer 0 2 minutes Fan runs at speed 2 Contact of S1 switch is OPENED Activation of turn off delay timer 2 30 minutes...

Page 20: ...urn off delay timer 5 minutes Contact of S1 switch is CLOSED Activation of turn on delay timer 45 seconds The contact of S1 switch is OPENED Yes No Fan runs at speed 2 Contact of S1 switch is OPENED H...

Page 21: ...2 Fan does not run Contact of S1 switch is CLOSED S1 switch in position Fan runs at speed 1 Fan runs at speed 2 Contact of S1 switch is OPENED 100 125 Ace Duo 17 DO NOT CLOSE CONTACTS S AND L WITH EA...

Page 22: ...22 EN QF L N 18 19 20 21...

Page 23: ...23 EN Quality Inspector s Stamp Manufacture Date Seller name and stamp of the seller Purchase Date...

Page 24: ...V160 2EN 01 Acceptance certificate The fan is recognized as serviceable V 220 V 60 Hz T 100 T1 L Ace 125 VT Duo TH VTH...

Reviews: