8. Open the access door of the unit and remove the 
heat recovery core.

9. Drill 2 Ø 1⁄4" holes in the wall and mount the unit onto 
it using screws and expansion anchors (included into 
delivery set). 

10. Install the heat recovery core and close the access 
door.

UNIT

TWO Ø 4 7/8 " AIR DUCTS

FOUR EXPANSION ANCHORS 
AND SCREWS

FOUR EXPANSION ANCHORS AND 
SCREWS (INCLUDED INTO OUTER 
HOOD DELIVERY SET) 

OUTER HOOD

Fig. 3. Unit mounting

CONNECTION TO POWER MAINS

DISCONNECT THE UNIT FROM THE POWER MAINS PRIOR TO ANY OPERATIONS.  

THE UNIT MUST BE PLUGGED INTO A PROPERLY INSTALLED POWER SOCKET WITH AN EARTHED TERMINAL. 

THE RATED ELECTRICAL PARAMETERS OF THE UNIT ARE SHOWN ON THE RATING PLATE. 

ANY TAMPERING WITH THE INTERNAL CONNECTIONS IS PROHIBITED AND WILL VOID THE WARRANTY.

The unit is designed for connection to 120 V / 60 Hz power supply source. 
The unit is supplied with a power cable and a plug. The unit must be connected to power mains through a grounded power socket  compliant with IEC 60884-1. The power cable is pre-
wired to the terminal block X1 by the manufacturer, fig. 4. 
Connect the unit to power mains through the external automatic circuit breaker integrated into the fixed wiring system. Install the circuit breaker to have a free quick access in case of 
need to turn the unit off promptly.  
The circuit breaker trip current must be in compliance with the current consumption. The recommended circuit breaker rated current is 2.5 A. While selecting the automatic circuit breaker 
consider the maximum wire temperature that depends on the wire type, insulation, length and layout way (open wire mounting, channel type or wall-mounted).