background image

CONTENTS

This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
The manual contains information about purpose, technical details, operating principle, design, and installation of the Airvents RH unit 
and all its modifications.
Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to 
work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country.

Safety requirements ..................................................................................................................................................................... 2
Purpose  ............................................................................................................................................................................................... 5
Delivery set  ....................................................................................................................................................................................... 5
Designation key  ............................................................................................................................................................................ 6
Technical data .................................................................................................................................................................................. 7
Unit design and operation logic .......................................................................................................................................... 8
Installation and set-up  .............................................................................................................................................................. 9
Connection to power mains  ................................................................................................................................................. 10
Technical maintenance  ............................................................................................................................................................ 10
Storage and transportation regulations .......................................................................................................................... 11
Certificate of acceptance .......................................................................................................................................................... 13
Seller information .......................................................................................................................................................................... 13
Installation certificate .................................................................................................................................................................. 13
Warranty card ................................................................................................................................................................................... 13

SAFETY REQUIREMENTS

THE UNIT MUST BE GROUNDED!
DO NOT BEND THE POWER CABLE.
AVOID DAMAGING THE POWER CABLE.
DO NOT PUT ANY FOREIGN OBJECTS ON THE POWER CABLE.
DO NOT USE DAMAGED EQUIPMENT OR CABLES WHEN CONNECTING THE UNIT 

TO POWER MAINS.
DO NOT TOUCH THE UNIT CONTROLS WITH WET HANDS.
DO NOT CARRY OUT THE INSTALLATION AND MAINTENANCE OPERATIONS 

WITH WET HANDS.
DO NOT ALLOW CHILDREN TO OPERATE THE UNIT.
DO NOT STORE ANY EXPLOSIVE OR HIGHLY FLAMMABLE SUBSTANCES IN 

CLOSE PROXIMITY TO THE UNIT.
DO NOT OPEN THE UNIT DURING OPERATION.
DO NOT BLOCK THE AIR DUCT WHEN THE UNIT IS SWITCHED ON.
DO NOT SIT ON THE UNIT AND AVOID PLACING FOREIGN OBJECTS ON IT.
UNPACK THE UNIT WITH CARE.
WHILE INSTALLING THE UNIT, FOLLOW THE SAFETY REGULATIONS SPECIFIC TO 

THE USE OF ELECTRIC TOOLS.
DO NOT LAY THE POWER CABLE OF THE UNIT IN CLOSE PROXIMITY TO HEATING 

EQUIPMENT.

2

Airvents RH

www.vents-us.com

Summary of Contents for Airvents RH

Page 1: ...Airvents RH Air handling unit USER S MANUAL...

Page 2: ...11 Certificate of acceptance 13 Seller information 13 Installation certificate 13 Warranty card 13 SAFETY REQUIREMENTS THE UNIT MUST BE GROUNDED DO NOT BEND THE POWER CABLE AVOID DAMAGING THE POWER C...

Page 3: ...ITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN READ THE US...

Page 4: ...PURCHASE DATE STAMP TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING USE THIS UNIT ONLY IN THE MANNER INTENDED BY THE MANUFACTURER IF YOU HAVE QUESTIONS CONTACT THE...

Page 5: ...pathogenic germs CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS AS WELL AS FLAMMABLE MIXTURES EVAPORATION OF CHEMICALS STICKY SUBSTANCES FIB...

Page 6: ...V01 AV02 AV03 AV07 AV12 CF counterflow R rotary P ceiling H double deck V vertical T rooftop 1000 1200 1500 2500 3500 5000 6000 9000 HE electric HW water _ no heater E enthalpy heat exchanger _ sensib...

Page 7: ...tection for the water drainage and connected pipelines must be provided during sub zero ambient temperatures if the unit is equipped with an air cooler The heat medium temperature in the water heat ex...

Page 8: ...TION LOGIC UNIT DESIGN 1 5 6 7 2 3 4 1 1 protective dampers with electric actuator optional 2 extract fan 3 rotary heat exchanger 4 supply filter 5 control unit 6 extract filter 7 supply fan 8 Airvent...

Page 9: ...act air Connection of the air ducts is shown with the stickers of the respective colours yellow for the extract air duct green for the intake air duct red for the supply air duct and brown for the exh...

Page 10: ...Open the service doors to access the filters AV03 Remove the two butterfly bolts that fix the retaining clamp AV02 Open the two latches securing the pressure plate Remove the filter elements WARNING...

Page 11: ...rmation Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit ca...

Page 12: ...se negligence accident improper maintenance or repair other than by Blauberg faulty installation or installation contrary to recommended installation instructions Labor to remove and replace products...

Page 13: ...___________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installa...

Page 14: ...14 Airvents RH www vents us com...

Page 15: ...15 www vents us com...

Page 16: ...VUSA192 2EN 02...

Reviews: