MANUFACTURER’S WARRANTY

Production meets standard operating requirements in the USA and Canada.
Vents US warrants to the original purchaser of the unit that it will be free from defects in materials or workmanship for a period of 
24 months from the date of original purchase. The Vents US warrants to the original purchaser of the unit that the integrated control unit 
will be free from defects in materials and workmanship for a period of 24 months from the date of original purchase.

THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, 

IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

During the stated warranty period, Vents US will, at its option, repair or replace, without charge, any product or part which is found to be 
defective under normal use and service. This warranty does not cover (a) normal maintenance and normal service or (b) any products 
or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Vents US), faulty 
installation or installation contrary to recommended installation instructions. Labor to remove and replace products is not covered. The 
duration of any implied warranty is limited to the time period specified for the express warranty. Some states do not allow limitations on 
how long an implied warranty lasts, so the above limitation may not apply to you.

VENTS US OBLIGATION TO REPAIR OR REPLACE, AT VENTS US OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE 

REMEDY UNDER THIS WARRANTY. VENTS US SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL 

DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.

Some states do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may 
not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. This 
warranty supersedes all prior warranties. If proof of sales date is absent, warranty period is calculated from the production date. The unit 
can be exchanged at the following address:

Vents-US
400 Murray Road, Cincinnati, OH 45217, USA
Tel: 1-888-640-0925, 513-583-5786, Fax: 513-268-4597
E-mail: [email protected] 
www.vents-us.com 

Please follow guidelines in this manual for product problem-free operation.

16

Airvents CFV

www.vents-us.com

Summary of Contents for Airvents CFV

Page 1: ...Airvents CFV Air handling unit USER S MANUAL...

Page 2: ...rer s warranty 15 Certificate of acceptance 19 Seller information 19 Installation certificate 19 Warranty card 19 SAFETY REQUIREMENTS THE UNIT MUST BE GROUNDED DO NOT BEND THE POWER CABLE AVOID DAMAGI...

Page 3: ...ITH REDUCED PHYSICAL MENTAL OR SENSORY CAPACITIES OR THOSE WITHOUT THE APPROPRIATE TRAINING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN READ THE US...

Page 4: ...H THE PURCHASE DATE STAMP TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING USE THIS UNIT ONLY IN THE MANNER INTENDED BY THE MANUFACTURER IF YOU HAVE QUESTIONS CONTA...

Page 5: ...substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs PURPOSE CAUTION FOR GENERAL...

Page 6: ...01 AV02 AV03 AV07 AV12 CF counterflow R rotary P ceiling H double deck V vertical T rooftop 1000 1200 1500 2500 3500 5000 6000 9000 HE electric HW water _ no heater E enthalpy heat exchanger _ sensibl...

Page 7: ...not included in the delivery set The frost protection for the water drainage and connected pipelines must be provided during sub zero ambient temperatures if the unit is equipped with air cooler The h...

Page 8: ...ater 3 electric heater only for the units with electric heater 4 supply fan 5 supply filter 6 extract fan 7 heat exchanger 8 extract fan 9 air flow control damper with electric actuator 10 bypass damp...

Page 9: ...of the air duct positioning For this purpose the side walls are plugged To change positioning of the air ducts use the plugs from the side walls for the front panel Supply air Exhaust air Intake air...

Page 10: ...ir Connection of the air ducts is shown with the stickers of the respective colours yellow for the extract air duct green for the intake air duct red for the supply air duct and brown for the exhaust...

Page 11: ...nd are stated in the table H h Total Fan Pressure Size H Size h Pa inWG mm in mm in 600 2 4 100 3 15 16 50 1 15 16 600 1000 2 4 4 140 5 1 2 70 2 3 4 1000 1400 4 5 6 190 7 1 2 95 3 3 4 1400 1800 5 6 7...

Page 12: ...for the models with water heater While connecting the water heater keep the straight air duct section length not less than 15 3 4 mm from the unit Otherwise the maintenance panel cannot be opened 15 3...

Page 13: ...not a malfunction Clean the unit to troubleshoot unpleasant odours Open the service doors to access the filters Remove the filter elements WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY T...

Page 14: ...To access the heat exchanger remove the holder 13 see page 7 Loosen the screws 1 on the retaining clamps 2 using a hexagon wrench 1 1 2 Pull the heat exchanger out 14 Airvents CFV www vents us com...

Page 15: ...operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transpo...

Page 16: ...gligence accident improper maintenance or repair other than by Vents US faulty installation or installation contrary to recommended installation instructions Labor to remove and replace products is no...

Page 17: ...___________________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installa...

Page 18: ...18 Airvents CFV www vents us com...

Page 19: ...19 www vents us com...

Page 20: ...VUSA192 5EN 02...

Reviews: