26
EN
STORAGE AND TRANSPORTATION REGULATIONS
• Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range
from +5 °C to + 40 °C and relative humidity up to 70 %.
• Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and
sealing deformation.
• Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit.
• Follow the handling requirements applicable for the particular type of cargo.
• The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation
and mechanical damage. The unit must be transported only in the working position.
• Avoid sharp blows, scratches, or rough handling during loading and unloading.
• Prior to the initial power-up after transportation at low temperatures, allow the unit to warm up at operating temperature
for at least 3-4 hours.
TROUBLESHOOTING
Problem
Possible reasons
Troubleshooting
When the unit is connected to power
mains, the fan does not rotate and
does not respond to any controls.
No power supply.
Make sure the power supply line
is connected correctly, otherwise
troubleshoot the connection error.
Internal connection fault.
Contact the Seller.
Low air flow.
The ventilation system is clogged.
Clean the ventilation system.
Increased noise, vibration.
The impeller is clogged.
Clean the impeller.
The fan is not secured well or is not
mounted properly.
Troubleshoot the installation error.
The ventilation system is clogged.
Clean the ventilation system.