ENGLISH

CERTIFICATION PLATE

Summary of Contents for HEI350

Page 1: ...IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH READ AND KEEP THIS MANUAL FOR REFERENCE Printed in Canada 2021 09 16 46255A ENGLISH 2 5 g h EPA Safety tested according to ULC S628 UL 1482 and UL 737 by an accredited laboratory US Environmental Protection Agency phase II certified wood insert compliant with 2020 cord wood standard HEI350 INSERT VB00021 Model Wood Insert Owner s Manual Part 2 of 2 IN...

Page 2: ...tablishes the warranty period If it can not be provided the warranty period will be determined by the date of manufacture of the product It is also highly recommended to register the warranty online at https www occanada com us en warranty registration Registering the warranty will help to quickly find the information needed on the unit Dealer Installer Phone Number Serial Number ...

Page 3: ...ENGLISH CERTIFICATION PLATE ...

Page 4: ...loor Protection 12 2 3 R Value 13 3 Installing Options on Your Product and Replacing Parts 15 3 1 Replacement and Adjustment 15 3 2 Blower and Ash Lip Installation 17 3 3 Faceplate and Trims Installation 18 3 4 Optional Fresh Air Intake Kit Installation 20 3 5 Log Retainers Installation 21 3 6 Optional Fire Screen Installation 22 3 7 Air Tubes and Baffle Installation 23 3 8 Removal Instructions 26...

Page 5: ... The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure 2 The maximum heat output dry cordwood is based on a loading density varying between 15 lb ft3 and 20 lb ft3 Other performances are based on a fuel load prescribed by the standard The specified loading densi...

Page 6: ...ULC S628 11 North south ends of the logs visible East west sides of the logs visible 12 Mobile homes Canada or manufactured homes USA The US Department of Housing and Urban Development describes manufactured homes better known as mobile homes as follows buildings built on fixed wheels and those transported on temporary wheels axles and set on a permanent foundation In Canada a mobile home is a dwe...

Page 7: ...3 4 706mm 9 1 8 232mm 24 1 4 615mm 24 1 2 621mm 24 7 8 633mm 1 7 8 49mm MIN 21 1 4 539mm MAX 29 735mm 24 1 8 614mm 23 1 8 586mm Figure 1 Top View Figure 2 Side View Minimum Insert Projection 11 1 2 291mm 18 3 8 467mm 27 5 8 701mm 18 3 8 466mm MIN 4 3 4 122mm MAX Figure 3 Front View Figure 4 Side View Maximum Insert Projection ...

Page 8: ...t Specification Manual HEI350 ENGLISH 19 483mm 9 1 4 236mm Figure 5 Door Opening 22 7 8 581mm 20 1 8 510mm 12 7 8 326mm 5 16 8mm 3 16 5mm Figure 6 Front View Combustion Chamber Figure 7 Side View Combustion Chamber ...

Page 9: ...oal bed and put six logs in the firebox of approximatively 4 x4 or 3 x3 Add the load in an East West configuration divided in 3 columns 2 smallest logs in the back 2 logs in the middle and 2 logs in the front Leave one inch of air space between the rear bricks and the first column another one inch between the first two columns and finally leave no space between the second and the third column Let ...

Page 10: ...MUM CLEARANCE FIGURES GIVEN 2 1 Minimum Masonry Opening and Clearances to Combustibles COMBUSTIBLE MANTEL SHELF COMBUSTIBLE TOP SURROUND COMBUSTIBLE SIDE SURROUND ADJACENT SIDE WALL FLOOR PROTECTION J I H Q G F K L O P Masonry Opening and Clearances MINIMUM CLEARANCES F 19 483 mm G 9 229 mm H 27 686 mm I 27 686 mm Q 84 213 cm MAXIMUM THICKNESS O 5 127 mm P 12 305 mm MINIMUM MASONRY OPENING J 26 66...

Page 11: ...ERIAL FLOOR PROTECTOR NON COMBUSTIBLE MATERIAL B C D E F A G HEARTH SLAB NON COMBUSTIBLE MATERIAL FLOOR PROTECTOR NON COMBUSTIBLE MATERIAL B C D E F A G Additional Floor Protection Raised Installation Additional Floor Protection Not Raised Installation 15 From door opening The depth of the hearth extension in front of the insert is included in the calculation of the floor protector s dimensions Th...

Page 12: ... the hearth extension of the masonry fireplace F 6 152 mm or less an R value equal to or greater than 2 00 is required and should extend at least 27 686 mm in front of the unit B Refer to Additional Floor Protection Not Raised Installation 2 2 2 Installation Raised of More Than 6 152 mm If the extension of the masonry hearth is raised at least 6 152 mm from the floor protection a non combustible m...

Page 13: ... 0 920 Exemple Required floor protection R of 1 00 Proposed materials four inches of brick and one inch of Durock board Four inches of brick R 4 x 0 2 0 8 plus 1 inch of Durock R 1 x 0 52 0 52 0 8 0 52 1 32 This R value is larger than the required 1 00 and is therefore acceptable In the case of a known K and thickness of alternative materials to be used in combination convert all K values to R by ...

Page 14: ... inspected periodically to check for a good seal The tightness of the door seal can be verified by closing and latching the door on a strip of paper The test must be performed all around the door If the paper slips out easily anywhere either adjust the door or replace the gasket 3 1 2 Adjustment The gasket seal may be improved with a simple latch mechanism adjustment 1 Remove the split pin by pull...

Page 15: ...s of the door using a 3 32 Allen key to free the adjustable hinge rods Using a flat screwdriver turn the adjustable hinge rods in the direction shown to adjust the doors Tighten all door hinge pressure screws when they are at the desired positions Configurations 1 2 3 4 5 6 show in which direction these act on the adjustment of the door 3 32 5 6 3 2 4 4 2 A B 1 3 ...

Page 16: ... gasket groove Starting from the middle hinges side press the gasket into the groove The gasket must not be stretched during installation 4 Leave about 10 mm long of the gasket when cutting and press the end into the groove Tuck any loose fibers under the gasket and into the silicone 5 Close the door Do not use the insert for 24 hours 3 2 Blower and Ash Lip Installation Note The images shown are f...

Page 17: ...d may be different from your product but the assembly remains the same 1 Remove the faceplate extension K secured between the firebox and the convection air jacket 2 Lay the panels on a flat and non abrasive surface Align the top panel holes L with the left N and right M panels Secure together using the four bolts P and nuts O provided ...

Page 18: ... height of the insert using the levelling bolts T on each side of the insert until the faceplate is properly seated on the floor of the hearth extension 5 Align the notch in the faceplate extension with the bolt Q welded to the air jacket located and slide the faceplate assembly just over the bolt s head and washer R Then push towards the fireplace 6 Once the faceplate is in place secure the assem...

Page 19: ...anual kit 1 Using pliers remove the rectangular metal plate retained by the micro gaskets to clear the opening for the outside air intake 2 Install the fresh air intake adapter B with four screws C then secure the flexible pipe18 E not included to the adapter using one of the pipe clamps B Secure the other end of the pipe to the outside wall termination F using the other pipe clamp The outside wal...

Page 20: ...Page 20 Product Specification Manual HEI350 ENGLISH 3 5 Log Retainers Installation 1 2 3 2 MIN 2 MIN ...

Page 21: ... only and may be different from your product but the assembly remains the same In the United States or in provinces with a particulate emissions limit e g US EPA the use of open door wood stoves with a rigid firescreen is prohibited 1 Open the door 2 Hold the fire screen by the two handles and bring it close to the door opening ...

Page 22: ...reen upwards and push the bottom part towards the insert then let the fire screen rest on the bottom of the door opening Warning Never leave the insert unattended while in use with the fire screen 3 7 Air Tubes and Baffle Installation 1 Starting with the rear tube lean and insert the right end of the secondary air tube into the rear right channel hole Then lift and insert the left end of the tube ...

Page 23: ...hold the tube and lock it in place by turning the tube as shown Make sure the notch reaches the end of the key way 3 Install the baffle 4 Repeat steps 1 and 2 for the three other tubes 5 To remove the tubes use the above steps in reverse order Note that secondary air tubes A can be replaced without removing the baffle board B and that all tubes are identical ...

Page 24: ...Page 24 Product Specification Manual HEI350 ENGLISH B A ...

Page 25: ...be removed To remove the insert follow these instructions Unscrew the faceplate fastener B holding the faceplate C on the insert Remove faceplate C by pulling on it Remove the blower assembly D Remove the three screws securing the pipe connector A Unscrew the bolts securing the insert to the floor on each side of the unit E ...

Page 26: ... Diagram and Parts List 2 1 3 4 6 7 5 9 10 17 16 34 40 37 41 45 43 43 33 12 14 11 15 27 18 19 20 25 26 22 21 23 24 30 31 28 28 32 39 36 35 42 44 46 47 48 49 50 53 52 52 52 52 52 52 52 52 52 52 53 53 52 52 52 53 52 52 52 51 51 51 51 51 51 51 51 54 54 54 54 29 38 8 13 ...

Page 27: ...GASKET 19 9 16 X 12 1 8 1 10 AC06400 3 4 X 6 FLAT BLACK SELF ADHESIVE GLASS GASKET 2 11 PL70979 GLASS FRAME 2 12 SE53585 GLASS RETAINER KIT WITH SCREWS 12 PER KIT 1 13 SE70988 GLASS FRAME KIT 1 14 SE70983 ASH SHELF ASSEMBLY 1 15 30507 BLACK TORX SCREW WITH FLAT HEAD TYPE F 1 4 20 X 3 4 3 16 AC05959 METALLIC BLACK STOVE PAINT 342 g 12oz AEROSOL 1 17 AC01298 5 Ø FRESH AIR INTAKE KIT 1 18 30206 ZINC ...

Page 28: ...VBA1557 32 X 44 REGULAR FACEPLATE 1 42 PL70987 HEI350 SIDE PANEL 32 X 44 2 43 SE15097 FACEPLATE HARDWARE KIT 2 44 PL70988 HEI350 TOP FACEPLATE 32 X 44 1 45 VBA1558 34 X 50 LARGE FACEPLATE 1 46 PL70989 HEI350 SIDE PANEL 34 X 50 2 47 PL70990 HEI350 TOP FACEPLATE 34 X 50 1 48 PL70864 SECONDARY AIR TUBE 4 49 21585 VERMICULITE BAFFLE 1 50 21564 C CAST 3 5 SERIE INSULATION TOP 1 51 PL36759 2 X 9 X 1 1 4...

Page 29: ...re limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective parts The manufacturer shall in no event be responsible for an...

Page 30: ...ional com This document is available for free download on the manufacturer s website It is a copyrighted document Resale is strictly prohibited The manufacturer may update this document from time to time and cannot be responsible for problems injuries or damages arising out of the use of information contained in any document obtained from unauthorized sources ...