Air Conditioner Service Manual
25
9. Installation manual
9.1 Installation Details
Connecting pipe length
Model
Pipe size(Inch)
Liquid
Gas
VAC-09CHSA/XA21 PLUS
1/4
3/8
VAC-12CHSA/XA21 PLUS
1/4
3/8
VAC-18CHSA/XA21 PLUS
1/4
1/2
VAC-24CHSA/XA21 PLUS
1/4
5/8
Mode
Standard
length: m
Refrigerant piping
Max. length: m
A
A
Additional refrigerant B
Calculation: ×g=Bg/m(A-5m)
VAC-09CHSA/XA21 PLUS
3.0
25
20g/m
VAC-12CHSA/XA21 PLUS
3.5
25
20g/m
VAC-18CHSA/XA21 PLUS
5.0
25
30g/m
VAC-24CHSA/XA21 PLUS
5.0
25
30g/m
Connecting cables
The power cord should be selected according to the following specifications sheet.
Appliance Amps
Wire Size
5
AWG21/0.75 mm2
10
AWG18/1.0 mm2
13
AWG15 /1. 5 mm2
18
AWG14/1.6 mm2
25
AWG12/2.0 mm2
30
AWG10/2.5 mm2
Outdoor unit
Pipe length is 15
meters Max.
H
ei
ght
sh
ou
ld
be
less
th
an
5m
Indoor unit
Outdoor unit
Pipe length is 15
meters Max.
Indoor unit
H
ei
ght
sh
ou
ld
be
less
tha
n
5m