VE-QF/VE-SF SILENT BATHROOM FAN
Passport / Opera
�on in
s
truc�on
Silent Bathroom Extractor Fan
EN
A
�
e
n�on!
Before using the appliance please read the contents of this ins
truc�on.
A
�
e
n�on!
Children of 8 years old and upward intend this appliance for use and persons with reduced
physical, sensory or mental capab
ili�
es, or lack of knowledge, unless a person responsible for
their safety has given them supervision or instruc
�
on concerning the use of the appliance
.
Children should be supervised to ensure that they do not play with the appliance
.
Cleaning and
service of the device shouldn’t to be made by children without supervision
.
Safety r
equi
r
emen
ts
A
�
e
n�on!
Specialists, who have a special allowance for such types of work, shall do c
onnec�on
of the fans to
power supply
.
The temperature of fan exploita
�on
cannot exceed the indicated range (from +1C to
+40C).
Avoid the installa
�on
of the fan to one ven
�l
a
�on
main line with smoke-de
flec�ng
pipe from devices,
having fuel burner
s.
In case of maintenance diagnos
�cs,
turn o
ff
the automa
�c
breaker (S1 in OFF
posi�on) and
c
all an electrician.
A
�
e
n�on!
All
ac�ons
for c
onnec�on,
set up, maintenance and repair of the product have to be carried out only
at mains voltage remov
ed (S1 in OFF posi�on).
One-phase main, to which the fan is connected, must correspond to the norms in for
ce.
Sta
�ona
ry
electric wiring must be equipped with an automa
�c
circuit breaker (S1 in the
scheme).
The c
onnec�on
is carried
out through the switch (S2 in the diagram) that is built into the sta
�ona
ry
wiring.
The gap between switch
contacts at all poles must be not less than 3
mm.
In the op
�on
«-02» the switch (S3 on the scheme) is built in the
f
an.
Before installa
�on,
it is necessary to make sure that there is no visible damage of impeller, case, grill, and the
fl
ow passage of the case has no any extraneous things, which may damag
e impeller blades.
Axial duct domes
�c
electric fan, axial duct domes
�c
removable electric fan is designed to remove
odors and excess moisture from toilets, bathrooms and other small rooms, required ven
�l
a
�on.
VE-QF/VE-SF SILENT BATHROOM FAN
Op
�ons
C, ET ,MR,
No o
p
�ons
EHT, C MRH
IP
25
24
S
ymbol le
g
end of o
p
�ons
Leg
end
Name
Axial duct domes
�c
removable electric f
ans with back fl
ow valve
MR
ET
Electric axial duct domes
�c
remov
able mul�o
p
�onal
fans with 2 modes and built in Fusion Logic
1.0.
controller
MRH
ETH
Electric axial channel household a
�achable mul�o
p
�on dual-mode
fan with built
-in Fusion Logic 1.1
Humidity sensors with electronic �mer pcb
Electronic �mer pcb
controller
.
name of color
options -C ET, EHT ,MR MRH
VE-QF , VE SF
Example
VE100-SF-C-ET
Main
t
echni
c
al cha
ract
eri
s
�cs
Cha
ract
eri
s
�cs
VE100-QF
VE125-SF
VE100-SF
VE-125QF
100
125
90
180
8,4
10
25
30
0,5
0,7
100
125
90
180
8,4
10
25
30
0,5
0,7
The fans are designed for c
onnec�on
to AC mains voltage 220-240 V, fr
equency 50/60 Hz.
In
st
all
a
�on and s
et up pr
ocedu
res
The Venteurope fans are mounted with ven
�l
a
�on
ducts or independently
.
The fans may be mounted to the ceiling, w
alls and all types of ceilings and par��ons with sc
rew
s.
S3
Legend of circuit breaker S1
on the scheme
Сircuit breaker S1
External switch S2
Built-in switch S3 (pull chain
switch)
Legend of external switch
S2 on the scheme
Legend of built-in switch S3 on
the scheme
Schem
a
�c diag
r
ams of
VE-QF/VE-SF SILENT BATHROOM FAN c
onnec�on
Scheme 1
of fan connectuion (base model)
X- terminal block, 2 pairs
220-240V
F* E C
Ød
X
A
Y
B
d
A
B
X
Y
E
F*
VE100-SF
100
155
155
135
135
70
7
24
VE125-SF
125
175
175
155
155
78
8,5
24
VE100-QF
100
155
155
135
135
70
7
24
VE125QF
125
175
175
155
155
78
8,5
24
*- This size is present only in f
ans with “back fl
ow valve”op
�on
VE-QF/VE-SF
(pic. 1)
• remove the decora
�
ve front panel
• hold the power wire through the cable hole 1 in the case
• strip the insula
�on on 5-7 mm f
rom the wire end
• insert wires into terminal box X and press them by tap screw
• fix the wi
res by means of cable clamp 2
• combine clamps of the decora
�
ve panel with grooves in the case
• fix the panel with sc
rew
2
3
1
Pic.1
VE-QF/VE-SF
Wiring diag
r
am
c
onnec�on of VENTEUROPE
f
ans
t
o the n
etwork
Connec�on of
fan to the network sho
wn in pic. 1
Main
t
enance
• disconnect the fan from the mains;
• remove the fan by disc
onnec�ng it f
rom the duct and removed from the installa
�on place.
• in case of heavy soiling, remove the fan impeller;
• wipe all plas
�c
components with a
so�
cloth soaked in soapy water, it is not allowed transfer of washing
solu�on
to the motor;
• wipe all surfaces dry;
• assemble a fan and se
t it in place.
Base on the type of protection from electric shock the fans relate to the devices of class ll
(220-240V/50-60 Hz). The climate category “moderately cold” Type 4
The level of protection against solid objects and water: