THIS GABLE-MOUNTED UNIT IS DESIGNED FOR ATTICS OF AVERAGE SIZE AND OPERATES MOST EFFICIENTLY WHEN AIR

INTAKES ARE LOCATED AROUND THE EAVES.  ALTERNATIVELY, AIR INTAKE MAY BE FROM OPPOSING GABLE VENTS, BUT

NEVER FROM ROOF OR RIDGE VENTS.   AT LEAST 600 SQ. IN OF NET FREE AIR INTAKE IS REQUIRED PER UNIT FOR SAFE

AND EFFICIENT OPERATION.  THE MOTOR OPERATES ON 120 V, 60 HZ, A.C. CURRENT.   SEE MOTOR LABEL FOR

AMPERAGE.

THIS UNIT MAY BE MOUNTED BEHIND ANY STATIC WALL VENT, OR MODELS VX1818 OR CX2121 AUTOMATIC SHUTTERS

.

Step 1

Step 3

For new installation or installation behind

existing louvers, using 2 x 4 studs, frame an

opening at least 18 ¼-in square (depending on

stud spacing) on center, on the attic side of the

gable.

Step 2

Cover the opening with a square piece of

plywood, paneling, or sheetrock, at least

21 ¼-in square (depending on stud spacing).

Cut a 15-in diameter hole in the center of this

panel, to allow the shroud of the fan to enter the

hole.

It is important to block off any remaining open

vent area in the gable.

With the nuts and bolts furnished, secure the 4

mounting brackets to the shroud and then

fasten the unit to the frame.

Mounting the long side of the

L brackets with the long side

to the shroud may better fit

your installation

and also help

reduce vibration.

Seal off any gaps

around the fan, in

order for the fan to function at maximum

efficiency

.

TIP

MUCH OF THE PREPARATION, WIRING OF 

THERMOSTAT, TESTING, AND MOUNTING TO THE

FRAME CAN BE DONE BEFORE FINAL INSTALLATION IN

THE ATTIC.