DIMENSIONS

MODEL

Rated Voltage 

(V/Hz)

Input

(W)

Air-flow

(m

3

/h)

Noise

(dB)

Size

(mm)

VSLF100

220-240V

~

50Hz

15

70

34

100mm

VSLF125

220-240V

~

50Hz

20

120

36

120mm

VSLF150

220-240V

~

50Hz

25

210

40

150mm

MAINTENANCE AND SERVICE

Before carrying out any maintenance, ensure the power is switched OFF from the mains 
power supply.

1.  Wipe down the fascia and grilles with a wet soapy cloth only. Do not allow water to have  
 

contact with the electrical parts, such as the motor.

2.  Never use petrol, benzene, thinner or any other chemicals for cleaning the    

 

 

ventilation fan.

3.  Do not immerse resin parts into hot water over 60°C.
4.  Do not place hot objects near or install nearby hot appliances.

Summary of Contents for PRO-V Slimline VSLF100

Page 1: ...INSTALLATION AND WIRING INSTRUCTIONS Slimline Exhaust Fans MODEL VSLF100 VSLF125 VSLF150 READ THE INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING ...

Page 2: ...led at least 120cm above any hotplate and must have at least 50cm clearance at the rear of the blades Minimum installation height is 2 1metres from the floor to the bottom of the exhaust fan If the room where the fan is to be installed already contains a stove water heater or a gas fire it is essential to ensure that the air supply to the room is enough for both the fan and the combustion applianc...

Page 3: ...throoms nearby sinks and water taps 2 For the exhaust fan to work efficiently replacement of air volume equivalent to what is being extracted must be able to enter the room In general this air would be drawn under the door or through a slightly opened window If the room is air tight the fan will function poorly Supply cable entry Terminal block Fig 3 ...

Page 4: ...e Live and Neutral supply wiring to the terminal block replace the terminal block cover and secure with screws 5 Secure the fan to the wall via the four screws and mounting holes 6 Replace the front panel and external shutter External shutter not supplied 1 Find a suitable location and cut the appropriate size diameter Ensure there are no cables or pipes above the ceiling when cutting 2 Remove the...

Page 5: ...ut any maintenance ensure the power is switched OFF from the mains power supply 1 Wipe down the fascia and grilles with a wet soapy cloth only Do not allow water to have contact with the electrical parts such as the motor 2 Never use petrol benzene thinner or any other chemicals for cleaning the ventilation fan 3 Do not immerse resin parts into hot water over 60 C 4 Do not place hot objects near o...

Reviews: