background image

Page 6

JCH/B1 0915A

11) FOR BACK VENTING APPLICATIONS ONLY. IF NOT BACK VENTING, PROCEED DIRECTLY TO STEP 12.

 

Note: Wall studs may interfere with back venting installations. Additional framing may be required. It is necessary to 

cut a duct access hole in the wall prior to installing the hood.

 

To accomplish this, first remove and set aside the duct cover that was previously installed in Step 8. Hold the hood 

on the mounting strip by aligning the channel at the top of the back of the hood over the wood mounting strip on the 

wall. Place the appropriate elbow on top of the hood in line with the hood exhaust collar. On the wall, trace around 

the elbow. Remove the hood and elbow from the wall. Cut around the outside of the traced line, avoiding wall studs. 

Install the duct from the outside of the home to the opening in the wall. Use duct tape to seal joints. Place the duct 

cover back onto the top of the hood and reattach it to the hood.

12) Hang the hood on the mounting strip by aligning the channel at the top of the back of the hood over the wood mounting 

strip on the wall. While holding the hood in place, mark locations on the mounting strip through the two mounting 

holes in the channel at the top of the hood. Some mounting holes may be located behind the blower(s). Remove hood 

and drill 3/32” pilot holes at the center of marks in the wood strip to prevent splitting.

13) FOR BACK VENTING APPLICATIONS ONLY. IF NOT BACK VENTING, PROCEED DIRECTLY TO STEP 14.

 

Place the appropriate elbow on the top of the hood. The elbow should be placed with the non-crimped end on the 

inside the collar of the exhaust outlet. Use duct tape to seal joint. Insert the electrical wire from the service panel into 

the electrical wire clamp on each motor box. Tighten the wire clamp(s). While securing the slack in the wire(s), lift the 

hood and duct cover up to the wall and hang the hood on the mounting strip, taking care to properly align the duct 

connection between the elbow on the hood and the duct in wall. Secure the hood to the mounting strip by installing 

the screws (previously removed in Step 10) into the pilot holes drilled in Step 12. SKIP STEPS 14 AND 15. PROCEED 

DIRECTLY TO STEP 16.

14) Insert the electrical wire from the service panel into the electrical wire clamp on each motor box. Tighten the wire 

clamp(s). Cut a piece of duct of sufficient length to meet the duct in the ceiling allowing room for the transition (if 

applicable). If a transition is used, cut the duct to reach the transition outlet plus 1”. This will allow the transition to 

engage 1” inside of the duct. See Page 3 for transition heights. One end of the duct must be crimped to fit inside the 

duct in the ceiling. Insert the non-crimped end over the transition or into the exhaust collar on the top of the hood and 

seal with duct tape.

15) While securing the slack in the wire(s), lift the hood and duct cover up to the wall and hang the hood on the mounting 

strip, taking care to properly align the duct connection between the hood and the duct in the ceiling. Secure the hood 

to the mounting strip by installing the screws (previously removed in Step 10) into the pilot holes drilled in Step 12.

16) From inside the hood, using UL listed wire nuts, attach the “neutral” wire(s) to the white lead(s), the “hot” wire(s) to 

the black lead(s), and the ground wire(s) to the green lead(s) inside the motor box(es).

Installation Details Continued

Warning:  Do not operate hood without  proper ground connection.

17) Plug the motor(s) into the hood and reinstall the blower motor(s) using the three retaining screws that were previously 

removed in Step 6.

18) Replace the blower housing(s) and the blower shield(s). Make sure that the damper(s) open and close smoothly.

19) Refer to the Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light 

functions to ensure they are operating properly.

Summary of Contents for JCH/B1 Series

Page 1: ...tion Included VP563 Standard Transition Included 36 30 6 Outlet Vent Hole 3 Electrical Centerline of Hood Wall Side 1 1 3 8 5 Electrical Mechanical Specifications For Blower Units Model Volts Amps Hz RPM CFM SP 0 0 Equivalent CFM CFM SP 0 1 CFM SP 0 2 CFM SP 0 3 Minimum Round Duct Size Sones B100 Single 115 2 5 60 1550 300 450 273 245 225 6 28 in 2 5 4 B200 Dual 115 4 0 60 1550 600 900 531 480 430...

Page 2: ...illing into wall or ceiling do not damage electrical wiring and other hidden utilities C Ducted fans must always be vented to the outdoors D Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the Nation...

Page 3: ...100 B200 10 round or equivalent 79 sq in VP562 Included Two Duals Two B200s 12 round or equivalent 113 sq in VP563 Included Ducting Requirements NEVER reduce the duct size When combining ducts together the square inch area must reflect the total square inch area of the ducts being combined Do not use flexible or corrugated duct This type of duct will restrict airflow and reduce performance Only us...

Page 4: ...next page for further details on exhaust outlet placement Use duct tape to seal all joints A complete listing of available Vent A Hood ducting materials is provided on the back page of this instruction sheet Transition heights are as follows Single Blower B100 6 round duct will connect directly to the top of the hood Dual Blower B200 8 round duct will connect directly to the top of the hood Single...

Page 5: ... 48 Widths 300 CFM B100 Single Blower Top View 600 CFM B200 Dual Blower Top View Front View Front View Connection Diagram 48 60 Widths The transition shown VP562 is installed in the hood at the factory as a standard item It will be located in the exact center of the duct cover left to right front to rear 900 CFM B200 Dual B100 Single Blower Top View VP562 Standard Transition Installed Front View C...

Page 6: ...ing from the service panel to the hood location for each motor box Consult the connection diagrams on previous page for further details on electrical placement Extend wire s to the hood Electrical connection s will occur before the hood is installed on the wall Warning Make sure power is off and locked at the service disconnecting means on the service panel during installation 5 Remove the shippin...

Page 7: ...cover up to the wall and hang the hood on the mounting strip taking care to properly align the duct connection between the elbow on the hood and the duct in wall Secure the hood to the mounting strip by installing the screws previously removed in Step 10 into the pilot holes drilled in Step 12 SKIP STEPS 14 AND 15 PROCEED DIRECTLY TO STEP 16 14 Insert the electrical wire from the service panel int...

Page 8: ...2 23 VP563 30 3 x 10 TO 7 TRANSITION MODEL DIM VP521 3 x 10 to 7 7 7 3 10 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 6 VP539 VP540 VP541 6 Round 7 Round 8 Round 16 16 LOW PROFILE ROOF JACK MAXIMUM 4 12 PITCH MODEL DIM 10 VP552 VP553 10 Round 12 Round 22 20 ADJUSTABLE ELBOW MODEL DIM VP513 VP514 VP515 6 Round 7 Round 8 Round 6 7 8 VP513 8 VP514 9 9 16 VP515 10 5 8 BACK SIDE VENT ELBOW MODEL...

Page 9: ...unt EPT NEPT SEPT C n a n a n a VP513 VP515 or VP561 n a 30 Tall Wall Mount C n a VP513 VP515 or VP561 VP513 VP515 or VP561 2 VP515 or 2 VP561 CWH B n a VP513 VP515 or VP561 VP513 VP515 or VP561 2 VP515 or 2 VP561 TILT Out TLH C n a VP513 VP561 n a n a JCH A1 Designer Series D n a VP513 VP515 or VP561 VP513 VP515 or VP561 2 VP515 or 2 VP561 JCH B1 Designer Series D n a VP513 VP515 or VP561 VP513 V...

Page 10: ...ew VP513 6 Round VP515 8 Round VP561 8 Round to 6 x 8 1 2 Rectangular 8 Round Diagram D Off the Top Within the Duct Cover Drawing Not To Scale Side View VP513 6 Round VP515 8 Round VP561 8 Round to 6 x 8 1 2 Rectangular 8 Round VP559 3 1 4 x 10 Rectangular VP561 8 Round to 6 x 8 1 2 Rectangular 7 Tall VP559 3 1 4 x 10 4 1 4 Tall VP513 6 Round 8 1 2 Tall When Fully Adjusted to 90 Degrees VP515 8 Ro...

Page 11: ...he KHSLD Liner Insert all Vent A Hood range hoods duct out the top and can be back vented only by use of transitions and or elbows Transition Heights VP559 3 1 4 x 10 Rectangular 4 1 4 Tall VP513 6 Round 8 1 2 Tall When Adjusted To 90 Degrees VP515 8 Round 10 3 4 Tall When Adjusted To 90 Degrees VP561 8 Round To 6 x 8 1 2 Rectangular 7 Tall K Series With VP559 Installed Back View B100 Blower Outle...

Page 12: ...nge Hood and the KHSLD Liner Insert all Vent A Hood range hoods duct out the top and can be back vented only by use of transitions and or elbows Transition Heights VP513 6 Round 8 1 2 Tall When Adjusted To 90 Degrees VP515 8 Round 10 3 4 Tall When Adjusted To 90 Degrees VP561 8 Round To 6 x 8 1 2 Rectangular 7 Tall B300 Blower Outlets With VP513 And VP561 Installed Back View B300 Blower Outlets Wi...

Page 13: ... Cabinet Range Hood and the KHSLD Liner Insert all Vent A Hood range hoods duct out the top and can be back vented only by use of transitions and or elbows Transition Heights VP513 6 Round 8 1 2 Tall When Adjusted To 90 Degrees VP515 8 Round 10 3 4 Tall When Adjusted To 90 Degrees VP561 8 Round To 6 x 8 1 2 Rectangular 7 Tall B400 Blower Outlets With 2 VP561s Installed Back View B400 Blower Outlet...

Page 14: ...ound VP527 7 Round VP528 8 Round MODEL DESCRIPTION PRICE VP554 10 Round MODEL DESCRIPTION PRICE VP555 12 Round MODEL DESCRIPTION PRICE VP538 6 x 8 1 2 VP560 3 1 4 x 10 MODEL DESCRIPTION PRICE VP539 6 Round VP540 7 Round VP541 8 Round MODEL DESCRIPTION PRICE VP552 10 Round VP553 12 Round MODEL DESCRIPTION PRICE VP539 HP 6 Round VP540 HP 7 Round VP541 HP 8 Round MODEL DESCRIPTION PRICE VP552 HP 10 R...

Page 15: ... BLOWER SWITCH KNOB P1450 M LINE LIGHT SWITCH P1455 M LINE LIGHT SWITCH KNOB P1456 M600 WIRING HARNESS P1457 M1200 WIRING HARNESS LIGHT BULBS PART NO DESCRIPTION PRICE P1110 GU10 HALOGEN BULB 50 WATT P1120 F15 T8 FLUORESCENT BULB 15 WATT P1130 PAR20 HALOGEN BULB 50 WATT LIGHT FIXTURE COMPONENTS PART NO DESCRIPTION PRICE P1101 SP2 BALLAST NEWER HOODS P1103 LEFT LAMPHOLDER P1104 RIGHT LAMPHOLDER P11...

Reviews: