background image

8

Maintenance and Cleaning

Daily

FILL with fresh tap water.

Every 10-14 days

RINSE lower housing and disk stack(s) 
with warm water. Wipe lower housing and fan
blade with soft cloth. RECHARGE with the 
recommended dose of Venta Water Treatment
Additive and fresh tap water.

Twice a year

CLEAN with ease. Use the Venta Cleaner periodically and the “one-click” technology
to thoroughly clean the Venta-Airwasher. See page 10 for instructions.

Or if you prefer, Venta-Airwasher offers a professional factory cleaning service. 
Call us toll-free (888) 333 8218 for details.

Anytime

Add a capful of one of our pure essential fragrance oils to provide aromatherapy.

Transportation

WARNING! Always switch off the motor and unplug the power cord from the A/C
outlet before moving the Venta-Airwasher.

Storage

We recommend a thorough cleaning of your Venta-Airwasher before storing the unit.
Please make sure that all components are clean and dry prior to storing. Do not leave
water in the lower housing when storing. Water left in the Venta-Airwasher may leave
mineral deposits and allow microorganisms to grow. Repack your Venta-Airwasher in
its original packaging and store in a cool dry place.

Technical 

data 

LW14 LW24 LW 

44

For rooms up to 

180 sq. ft. (12’ x 15’) 

360 sq. ft. (18’ x 20’) 

720 sq. ft.

Disk surface 

15.3 sq. ft. 

22.5 sq. ft. 

45 sq. ft.

Air throughput 

54 cu.ft/min. 

73 cu.ft/min. 

150 cu.ft/min.

Speeds 

2 3 3

Sound level 

30/34 dBA 

32/37/42 dBA 

32/37/42 dBA

Dimensions 

9.5 x 10.5 x 11.8 in. 

11.5 x 11.8 x 13 in. 

16.5 x 11.8 x 13 in.

Weight (empty) 

approx. 7 lb. 

approx. 9 lb.

approx. 13 lb.

Energy consumption 

approx. 32 watts 

approx. 42 watts 

approx. 42 watts

Water reservoir 

1.2 gallons 

2 gallons 

3 gallons

Warranty 

10 years 

10 years 

10 years

Extremely low power consumption. Above square feet is based off eight foot ceilings.

Summary of Contents for LW 14

Page 1: ...READ AND SAVE THESE IMPORTANT INSTRUCTIONS Venta Airwasher User Manual For models LW 44 LW 24 LW 14 Made in Germany ...

Page 2: ...tion is far more effective Many airborne particles fall to the floor when moistened Impurities of the air and odors are trapped in the water and eliminated while pure water evaporates Your investment in the Venta Airwasher humidifier will certainly prove worthwhile Dry mucous membranes cannot intercept bacteria and stale tobacco smoke imposes a strain on the respiratory tract Not only will you be ...

Page 3: ... not attempt any repair work Maintenance or servicing the Venta Airwasher other than described in this user manual should only be done by Venta Any modification to your Venta Airwasher is extremely dangerous and voids your warranty I Do not insert any objects into the air intake of the unit It may damage the fan blades or cause injuries After the motor is switched off the fan continues to rotate f...

Page 4: ...board 5 Remove the package containing two 2 bottles of Venta Water Treatment Additive WTA On the LW 44 these are packed in the upper housing Keep the packaging if you plan to safely store your Venta Airwasher during the summer months or in case of warranty repair How does the Venta Airwasher improve your dry indoor air Dry air is drawn in through the top of the Venta Airwasher and passes over a ro...

Page 5: ...oximately one 1 inch below the top on the inside of the lower housing You can transport the lower housing to your sink or tub or you may fill the lower housing by carrying the water in a pitcher or watering can to the lower housing Be careful when filling cleaning or moving the Venta Airwasher to avoid water spills Do not fill your Venta through the air intake holes on top of the upper housing 6 A...

Page 6: ... time to reduce the fan speed setting one step Press MINUS button until the white marker is above ZERO 0 the unit shuts off Although the motor is shut off the fan blades may continue to rotate for a short period of time I The Venta Airwasher has a built in automatic safety shut off switch As soon as the upper housing is lifted off the lower housing the motor shuts off even though the fan blades ma...

Page 7: ...2 4 3 6 3 5 4 1 Switch the motor off and unplug the power cord 2 To open upper housing unit for easy access to components press simultaneously both tabs next to the speed controls One Click Technology unlocks the upper housing 3 Lower the 2 long vented sides 4 Lower the 2 short solid sides 5 Push up trap door and remove cord from its track 6 Easily lift out the motor housing ...

Page 8: ...commend a thorough cleaning of your Venta Airwasher before storing the unit Please make sure that all components are clean and dry prior to storing Do not leave water in the lower housing when storing Water left in the Venta Airwasher may leave mineral deposits and allow microorganisms to grow Repack your Venta Airwasher in its original packaging and store in a cool dry place Technical data LW14 L...

Page 9: ...e s back label Shake well before use CAUTION KEEP OUT OF REACH OF CHILDREN EMERGENCY FIRST AID TREATMENT Eye and skin irritant In the event of contact with eyes flush thoroughly with water In the event of skin contact rinse with water Harmful if swallowed Do not induce vomiting Seek medical attention Venta Water Treatment Additive is recommended for use with Venta Airwasher humidifiers only Shelf ...

Page 10: ... flush thor oughly with water In the event of skin contact rinse with water CONTAINS Water and citric acid WARNING Venta Cleaner is recommended for use with the Venta Airwasher only Shelf life when stored cool and away from sunlight see expiration date EXP MONTH YEAR on bottle front label Venta Cleaner is not suitable for ultrasonic heat vaporizing or atomizing type vaporizer humidifiers Venta Cle...

Page 11: ...and clothing Prolonged contact with skin may cause allergic reaction DO NOT ingest FIRST AID TREATMENT If in eyes immediately flush eyes with water seek medical attention If on skin wash with soap and water If swallowed DO NOT induce vomiting Rinse mouth with water and call physician or poison control center immediately CONTAINS fragrance oils Wash hands after handling To learn more about the frag...

Page 12: ... housing sitting properly on the lower housing The automatic safety switch won t allow the motor to run unless the upper housing is sitting properly on the lower housing I Is there electrical power in the outlet Try to plug the power cord into a different 110 120V A C outlet I Turn the motor to the ZERO 0 off position unplug the power cord from the electrical outlet Remove the gear from the upper ...

Page 13: ...ance This warranty does not cover normal wear of parts or damage resulting from any of the following Negligent use or misuse of the product use on improper voltage or current use contrary to the operating instructions disassembly repair or alteration by anyone other than Venta Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes Venta shall not be liable for ...

Page 14: ...Switch the unit off to ZERO position 2 Unplug the power cord from the A C outlet 3 Remove the motor housing from the upper housing 4 Remove the coupling from the gear by pushing the coupling down toward the fan and away from the gear 5 Pivot turn the gear 90 degrees so it is laying on its side 6 Gently pull one of the two motor housing arms approximately 1 8 of an inch away from the gear and remov...

Page 15: ...e gear until it fits tight On models with a small white pin first insert the pin through the rubber coupling and then push both up into the gear until it fits tight Check that this is properly seated by spinning the fan with your hand The teeth in the gear should slowly move in and out Service Option Venta Airwasher In case you prefer the factory to handle your concern for warranty repair or if yo...

Page 16: ...Venta Airwasher LLC 1360 Hamilton Parkway Itasca Illinois 60143 Phone 630 285 1188 Fax 630 285 1187 www venta airwasher com Made in Germany ...

Reviews: