2
VENT-AXIA VISIONEX MAINS 220-240V FITTING AND WIRING INSTRUCTIONS
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
OPERATION
Visionex always looks for movement within its range. A hot body moving across the detection zones will activate
the Visionex which will switch on the connected load. If the body becomes still or moves out of range, the Visionex
stays on for an adjustable overrun time and then switches the connected load off.
The Visionex PIR controller has been designed for maximum versatility. It has a single pole relay with a
changeover contact.
SITING
The Visionex must not be installed in a shower cubicle or enclosure. It must be sited away from direct
sources of water spray and out of reach of a person using a fixed bath or shower.
Ambient temperature range: 0 to 40°C. Site away from direct sources of heat. Do not site above a radiator or other
heat source. Do not site in an area containing excessive levels of grease. Do not place in direct sunlight as this
may affect the sensor.
FITTING
The Visionex is designed to fit any UK single mounting box with a minimum depth of 20mm. Fixing centres
60.3mm. A surface mounting box is available (Vent-Axia Ref. 410020).
WIRING
WARNING: For your safety please ensure that the mains
supply is isolated before making electrical connections.
The Controller MUST be connected to a 220-240V 50Hz AC
single phase mains supply.
WARNING: The Visionex MUST NOT be earthed. It is Class II double insulated.
However, if the Visionex is
mounted on a metal outlet box the outlet box should be earthed. If the fan requires an earth connection then earth
continuity must be provided.
All electrical connections should be made by a properly
qualified electrician. The siting and installation MUST
comply with the current I.E.E. Regulations (BS7671 UK) or
the appropriate standards in your country.
This appliance is not intended for use by persons
(Including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible
for their safety. Children should be supervised to ensure
that they do not play with the appliance.
DO NOT connect more than one fan to the Visionex. The maximum load is 600W (Inductive or Resistive).
Note: Visionex does not need a lamp connected in the input or output circuit.
Wiring should be via a fused switched spur fitted with a fuse to suit the appliance being used. The installation
MUST be provided with a double pole isolator switch with a contact separation of at least 3mm. The switch should
be located outside the room if it contains a fixed bath or shower, or in accordance with mandatory wiring and safety
regulations.