L.
Stationary appliances not fitted with means for disconnection from
the supply mains having a contact separation in all poles that
provide full disconnection under over voltage category III, the
instructions state that means for disconnection must be
incorporated in the fixed wiring in accordance with the wiring rules.
M.
Ensure the grille is fully engaged onto the fan chassis using all
clips.
N.
Cleaning and user maintenance shall not be made by children.
ACCESSORIES
(not supplied)
WALL FITTING KIT
A range of 100mm wall kits are available for installing into most walls using telescopic liners
supplied.
WINDOW FITTING KIT
For use in single or sealed double
glazing and most materials up to
40mm thick.
INSTALLATION
IMPORTANT:
The fan should only be used in
conjunction with fixed wiring.
PANEL/CEILING MOUNTING
1.
For panel/ceiling mounting the fan should be
installed into a closed duct protected by an exterior
air grille that must comply with the standard
requirements of your country.
2.
Cut a 105mm diameter hole for 100mm fans.
3.
Push the two clips on each side of the fan and pull
the grille away from the chassis.
4.
Using the built in spirit level bubble as an aid. Mark
the screw centres through the holes in the fan back
plate. Drill, plug and screw into position.
5.
After installation, ensure impeller rotates freely and
the shutters can open.
6.
Replace the grille and ensure the clips reactivate.
WALL MOUNTING
1.
For wall mounting either cut a 115mm diameter hole for 100mm fans, through the wall and insert the
wall sleeve. Slope the sleeve slightly downwards away from the fan. Cut to length and cement both
ends into position flush with the wall faces.
2.
Push the two clips on each side of the fan and pull the grille away from the chassis.
3.
Using the built in spirit level bubble as an aid. Mark the screw centres through the holes in the fan
back plate. Drill, plug and screw into position. Fix exterior grille into position with the louvres
positioned downwards. (Note:- The grille must comply with the standard requirements of your
country. The wall kit used in this installation should provide a minimum ducting length of 100mm
from the fans back plate to the inside of the external grille).
4.
After installation, ensure impeller rotates freely and the shutters can open.
5.
Replace the grille and ensure the clips reactivate.
Stock
Reference
White
Brown
Wall Fitting Kit
100mm 254102 254100
Window Fitting Kit
100mm 442947 -
Spirit level used
only for cosmetic
help. Not essential
for the normal
working of the fan.