Operating and installation instructions
DO NOT
install this product in areas where the
following may be present or occur:
• Excessive oil or a grease laden atmosphere.
• Corrosive or flammable gases, liquids or vapours.
• Ambient temperatures are outside 5-50°C.
• Possible obstructions which would hinder the access or
removal of the Fan.
SAFETY AND GUIDANCE NOTES
A. All wiring to be in accordance with the current I.E.E.
Regulations, or the appropriate standards of your
country and MUST be installed by a suitably qualified
person.
B. The Fan should be provided with a local isolator switch
capable of disconnecting all poles, having a contact
separation of at least 3mm.
C. Ensure that the mains supply (Voltage, Frequency, and
Phase) complies with the rating label.
D. The Fan should only be used in conjunction with the
appropriate Vent-Axia products.
E. The fan should only be used in conjunction with fixed
wiring.
F. The Fan should not be used where it is liable to be
subject to direct water spray for prolonged periods of
time.
G. Where ducted Fans are used to handle moisture-laden
air, a condensation trap should be fitted. Horizontal
ducts should be arranged to slope slightly downwards
away from the Fan.
H. This appliance is not intended for use by young children
or infirm persons without supervision.
I. Young children should be supervised to ensure that they
do not play with the appliance.
J. The exterior grille should be at least 2.3m above the
ground to prevent people from being able to access
moving parts. If the external grille is positioned
between 0-2.3m from the ground, please use the Vent-
Axia wall kit to ensure people cannot access the fans
impeller from the outside.
Important:
READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION