IMPORTANT SAFETY INFORMATION

1.  DO NOT install this product in areas where the following may be present or occur:

2.  Excessive oil or a grease laden atmosphere.

3.  Corrosiveorflammablegases,liquidsorvapours.

4.  Subject to direct water spray from hoses.

5.   Ambient temperatures higher than 40°C or less than –20°C.

6.   Possible obstructions which would hinder the access or removal of the Fan.

7.  AllwiringmustbeinaccordancewiththecurrentIEEwiringregulationsBS7671,or

appropriate standards of your country. Installation should be inspected and tested by a 

suitablyqualifiedpersonaftercompletion.

8.  Ensurethemainssupply(voltage,frequencyandphase)complieswiththeratinglabel.

9.  A means for electrical disconnection must be incorporated in the fixed wiring to the unit 

in accordance with the wiring rules having a contact separation in all poles of at least 

3mm.

10. These units must be earthed.

11. Precautions must be taken to avoid the back-flow of gases into the building from the 

open flue of gas or other fuel-burning appliances.

12. Thisapplianceisnotintendedforusebypersons(includingchildren)withreduced

physical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unless

they have been given supervision or instruction concerning use of the appliance by a 

person responsible for their safety.

13. Young children should be supervised to ensure that they do not play with the 

appliance.

14. CAUTION: In order to avoid a hazard due to inadvertent resetting of the thermal cut-

out,thisappliancemustnotbesuppliedthroughanexternalswitchingdevice,suchas

atimer,orconnectedtoacircuitthatisregularlyswitchedonandoffbytheutility.

15. These units are rated IP22 and are not suitable for outside use.

INSTALLATION GUIDANCE:

1.  The installer is responsible for the installation and electrical connection of the system on site. It is the responsibility 

oftheinstallertoensurethattheequipmentissafelyandsecurelyinstalledandleftonlywhenmechanicallyand

electrically safe.

2.  Shortductrunsterminatingclosetothefan(i.e.within1.5m)requiresuitableguards.

3.  Allregulationsandrequirementsmustbestrictlyfollowedtopreventhazardstolifeandproperty,bothduringand

afterinstallation,andduringanysubsequentservicingandmaintenance.

4.  Certainapplicationsmayrequiretheinstallationofsoundattenuationtoachievethesoundlevelsrequired.

5.  SLPECunitsaredesignedandspecifiedforusewithVent-Axiacontrols,dampers,grillesandaccessories.

6.  Allmainsconnectionstotheunitusingflexiblewiringoranyadditionalcontrolswiringmustusecableglands

sufficienttoretaintheIPratingoftheunitandprovidecableretentiontotherequirementsofEN60335-1 

Clause 25.15.

7.  Thefixingsandanchorsusedtosuspendandmounttheunitmustbecompatiblewiththeunit’sweight. 

Suitable drop rods and anti-vibration mounts can be used.

8.  Due to the weight of the units it is recommended that two people are involved in the installation.

9.  Itisrecommendedthatflexibleconnectionsareusedbetweentheunitandrigidducting.

IMPORTANT: READ THESE INSTRUCTIONS

BEFORE COMMENCING THE INSTALLATION

Summary of Contents for Slimpak EC Series

Page 1: ...Range SLP EC Installation and Wiring Instructions SLP100EC SLP125EC SLP150EC SLP200EC SLP250EC SLP315EC SLP400EC SLP500EC PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION THESE INSTRUCTIONS SHOULD BE LEFT WITH THE END USER ...

Page 2: ...g of the thermal cut out this appliance must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility 15 These units are rated IP22 and are not suitable for outside use INSTALLATION GUIDANCE 1 The installer is responsible for the installation and electrical connection of the system on site It is the responsi...

Page 3: ... 1b For floor or ceiling mounting SLP100EC SLP125EC SLP150EC SLP200EC SLP250EC SLP315EC SLP400EC SLP500EC For floor or ceiling mounting Fixing locations Fixing locations Fixing locations Fixing locations ...

Page 4: ...2 Cable entry locations mains wiring cable entry control wiring cable entry SLP100EC SLP125EC SLP150EC SLP200EC SLP250EC control wiring cable entry mains wiring cable entry SLP315EC SLP400EC SLP500EC ...

Page 5: ... phase terminals single fan SLP315EC SLP400EC L1 L2 L3 Three phase terminals single fan SLP500EC Control panel wiring for external speed control 10V 0V 0 10V MIN SPEED MAX EX INT Internal speed control ONLY Move switch to EX position 10V 0 10V GND L1 L2 L3 X L N Single fan units with external mains connection access Note X is not used Note X is not used 4 ALL UNITS ...

Page 6: ... g h i WEIGHT kg SLP100EC 100 380 275 456 310 192 155 108 96 7 5 SLP125EC 125 380 275 456 310 192 155 108 96 7 5 SLP150EC 150 380 275 456 310 192 155 108 96 7 5 SLP200EC 200 435 330 511 364 287 182 122 143 12 SLP250EC 250 435 330 511 364 287 182 122 143 13 SLP315EC 315 710 540 785 572 460 286 243 230 33 SLP400EC 400 710 540 785 572 460 286 243 230 36 SLP500EC 500 898 735 975 770 577 385 326 286 58...

Page 7: ......

Page 8: ...oad Crawley West Sussex RH10 9JA SALES ENQUIRIES Tel 0844 8560590 Fax 01293 565169 TECHNICAL SUPPORT Tel 0844 8560593 Fax 01293 539209 For details of the warranty and returns procedure please refer to www vent axia com or write to Vent Axia Ltd Fleming Way Crawley RH10 9YX 475381B 06 17 ...

Reviews: