3
Technical Data
Maximum airflow
140 m³/h or 39l/s
Min sound level
19 dB (A) 3 m
Max pressure
57 Pa
Power consumption
2 - 5 W
Spigot depth
29 mm
Hole size
105 - 130 mm
Material
ABS plast
Protection rating
IP44
Insulation class
X
Voltage frequency
100 - 240V AC
50 - 60 Hz
Certificates
DC6
Mounting options
Wall or ceiling
Bluetooth LE
-12dBm EIRP (63μW),
nominellt
2450MHz
Dimensions (mm)
Settings
Press the function icon and all adjustable/programmable
symbols will light up. Then press any of the Timer, Humidity
control, Continuous or Light/Odour.
This will only light up the selected function, which is then
ready for adjustment. You can control speed/flow
+/- is provided for certain functions. Lit lamps next to each
symbol indicates the function is selected.
See the Vent-Axia website for detailed information on all
fan functions with and without the app: www.vent-axia.com
Default Factory Settings
Constant running low speed
ON - 10l/s
Airing function (every 26hr)
ON - 15l/s 60min
Overrun timer
ON - 15l/s 15min &
2min
Delay
Humidity function
ON - 28l/s
Light sensor
OFF - 15l/s
Odour sensor
ON - 28l/s
Reset
Press the function button once. Press and hold the function
button for at least 5 seconds.
Speed
Timer
Function
Humidity control
Continuous
Light, Odour &
Bluetooth App
Connectivity Sensor
A
B
C
D
EØ
FØ
185
160
40
28.5
100
125
A
C
D
B
EØ
FØ
A
C
B
EØ FØ
D
Vent-Axia hereby assure that this type of Bluetooth radio
equipment complies with RED Directive 2014/53 / EU. The
full text of the EU Declaration of Conformity can be found at
the following URL: http://bit.ly/3114hXl