Technical Data

Maximum airflow 

 

140  m³/h or 39l/s 

Min sound level  

 

19  dB  (A) 3  m

Max pressure   

 

57  Pa

Power  consumption 

 

2  -  5  W

Spigot depth   

 

29  mm

Hole  size   

 

 

105  -  130  mm

Material  

 

 

ABS plast

Protection rating 

 

IP44

Insulation class  

 

X

Voltage  frequency 

 

100  -  240V  AC   

 

 

 

 

 

50  -  60  Hz

Certificates  

 

DC6 

Mounting options 

 

Wall or ceiling

Bluetooth LE   

 

-12dBm EIRP (63μW),    

  

 

 

nominellt 

2450MHz

Dimensions (mm)

Settings

Press the function icon and all adjustable/programmable 
symbols will light up. Then press any of the Timer, Humidity 
control, Continuous or Light/Odour.
This will only light up the selected function, which is then 
ready for adjustment. You can control speed/flow
+/- is provided for certain functions. Lit lamps next to each 
symbol indicates the function is selected.
See the Vent-Axia website for detailed information on all 
fan functions with and without the app: www.vent-axia.com

Default Factory Settings

Constant running low speed  

ON - 10l/s  

Airing function (every 26hr)  

ON - 15l/s 60min  

Overrun timer  

 

ON - 15l/s 15min &    

   2min 

Delay 

 

 

Humidity function  

 

ON - 28l/s  

Light sensor  

 

OFF - 15l/s

Odour sensor  

 

ON - 28l/s

Reset

Press the function button once. Press and hold the function 
button for at least 5 seconds.

Speed

Timer

Function

Humidity control

Continuous 

Light, Odour & 
Bluetooth App 
Connectivity Sensor

A

B

C

D

185

160

40

28.5

100

125

A

C

D

B

A

C

B

EØ FØ

D

Vent-Axia hereby assure that this type of Bluetooth radio 
equipment complies with RED Directive 2014/53 / EU. The 
full text of the EU Declaration of Conformity can be found at 
the following URL: http://bit.ly/3114hXl

Summary of Contents for PUREAIR SENSE

Page 1: ...Bathroom Fan with Odour Sense Technology P U R E A I R S E N S E A product by Instruction Manual...

Page 2: ...djustable Timer Triggered via light sensor Possibility of a 2 minute delay and selectable run on time 15 or 30 minutes The airflow can be adjusted from the control panel or via the app Automatic Humid...

Page 3: ...ons Lit lamps next to each symbol indicates the function is selected See the Vent Axia website for detailed information on all fan functions with and without the app www vent axia com Default Factory...

Page 4: ...tch see wiring diagram 2 The fan is connected with constant voltage supply 100 240 VAC 50 60 Hz phase L and Zero N The control phase SL is connected to activate the fan s time control i e when the bat...

Page 5: ...ng Capacity Curve Maximum flow and available pressure 140 m 39l s h_57 Pa with 118mm 125 adapter 30 20 10 0 50 40 60 Pressure Pa Volume Flow l s 0 10 5 15 25 35 20 30 40 1 2 1 2 100 max speed 125 max...

Page 6: ...6 1 2 3 Mounting 4 108 98 100 98 127 133 118 125 118 1 2 Min 200 mm min 200 mm...

Page 7: ...7 5 9 6 10 11 7 Installation 92 112 40 40 40 40 46 56 20 20 13 A B B B B B A 124 124 1 x4 2 x4 3 x4 4 x1 Min 120mm Min 80mm 8...

Page 8: ...8 SL L N SL L N 12 14 15 16 13 SL L N SL L N SL L N SL L N 1 2 3 L N SL L N SL L N 100 240VAC 50 60Hz SL L N...

Page 9: ...he fan to work correctly it must be cleaned regularly The cleaning interval is determined by how long the fan is operated and the air quality Clean the fan at least twice year or as necessary When cle...

Page 10: ...a normal residential environment must be connected to a voltage of 100 240VAC 50 60Hz has not been exposed to lightning or abnormal power surges has not been subjected to tampering has been installed...

Page 11: ...fan are connected Please visit the Downloads section of the Pure Air Sense product page on our website for further instructions on using all the app functions www vent axia com pureairsense 2 With you...

Page 12: ...r Select time Activate deactivate delayed start Increase decrease airflow One press at a time Hold for 2 secs The lamps flash 3 times Press the buttons 15 min 30 min 15 min 30 min Humidity Control The...

Reviews: