Vent-Axia LuminAir Turbo Series Installation And Wiring Instructions Download Page 7

 7

 

PRODUCT FICHE 

For Residential Ventilation Units (Complying Commission Delegated Regulation (EU)               No 1254/2014) 

 

Name:

  

Vent

Axia

 

Vent

Axia

 

Model

 

ID

 

(Stock

 

Ref.)

 

:

 

LuminAir

 

Turbo

 

SKL

 ‐ 

453419C

 

LuminAir

 

Turbo

 

SKT

 ‐ 

453422C

 

SEC

 

Class

 

E

 

E

 

SEC

 

Value

 

('Average')

 

17.15

 

18.74

 

SEC

 

Value

 

('Warm')

 

7.76

 

8.48

 

SEC

 

Value

 

('Cold')

 

33.55

 

36.67

 

Label

 

Required?

 

(Yes/No=Out

 

of

 

scope)

 

No

 

No

 

Declared

 

as:

 

RVU

 

or

 

NRVU/UVU

 

or

 

BVU

 

RVU

UVU

 

RVU

UVU

 

Speed

 

Drive

 

on/off

 

Single

 

Speed

 

on/off

 

Single

 

Speed

 

Type

 

HRS

 

(Recuperative,

 

Regenerative,

 

None)

 

None

 

None

 

Thermal

 

Eff:

 

[

 

(%),

 

NA(if

 

none)]

 

N/A

 

N/A

 

Max.

 

Flow

 

Rate

 

(m3/h)

 

158.40

 

158.40

 

Max.

 

Power

 

Input

 

(W):

 

(@Max.Flow

 

Rate)

 

15.00

 

15.00

 

LWA:

 

Sound

 

Power

 

Level

 

(dB)

 

55.52

 

55.52

 

Ref.

 

Flow

 

Rate

 

(m3/s)

 

0.03

 

0.03

 

Ref.

 

Pressure

 

Diff.

 

(Pa)

 

N/

A

 

N/

A

 

SPI

 

[W/(m3/h)]

 

0.14

 

0.14

 

Control

 

Factor

 

&

 

Control

 

Typology:

 

(CTRL/

 

Typology)

 

  

  

Control

 

Factor;

 

CTRL

 

1.00

 

0.95

 

Control

 

Typology

 

Manual

 

Control

 

Clock

 

Control

 

Declared:

 ‐

Max

 

Internal

 

&

 

External

 

Leakage

 

Rates(%)

 

for

 

BVUs

 

or

 

carry

 

over

 

(for

 

regenerative

 

heat

 

exchangers

 

only),

                                                   

&Ext.

 

Leakage

 

Rates

 

(%)

 

for

 

Ducted

 

UVUs;

 

N/

A

 

N/

A

 

Mixing

 

Rate

 

of

 

Non

Ducted

 

BVUs

 

not

 

intended

 

to

 

be

 

equipped

 

with

 

one

 

duct

 

connection

 

on

 

either

 

supply

 

or

 

extract

 

air

 

side;

 

N/A

 

N/A

 

Position

 

and

 

description

 

of

 

visual

 

filter

 

warning

 

for

 

RVUs

 

intended

 

for

 

use

 

with

 

filters,

 

including

 

text

 

pointing

 

out

 

the

 

importance

 

of

 

regular

 

filter

 

changes

 

for

 

performance

 

and

 

energy

 

efficiency

 

of

 

the

 

unit

 

N/

A

 

N/

A

 

For

 

UVUs

 

(Instructions

 

Install

 

Regulated

 

Supply/Extract

 

Grilles

 

Façade)

 

In

 

F&W

 

In

 

F&W

 

Internet

 

Address

 

(for

 

Disassembly

 

Instructions)

 

www.vent

axia.com

 

www.vent

axia.com

 

Sensitivity

 

p.

 

Var20/

20

 

Pa:

 

(for

 

Non

Ducted

 

Vus)

 

N/

A

 

N/

A

 

Air

 

Tightness

ID/OD

(m3/h)

 

(for

 

Non

Ducted

 

Vus)

 

N/

A

 

N/

A

 

Annual

 

Electricity

 

Consumption:

 

AEC

 

(kWh/a)

 

1.69

 

1.61

 

Annual

 

Heating

 

Saved:

 

AHS

 

(kWh/a)

 

  

  

AHS:

 

Average

 

17.15

 

18.74

 

AHS:

 

Warm

 

7.76

 

8.48

 

AHS:

 

Cold

 

33.55

 

36.67

 

Summary of Contents for LuminAir Turbo Series

Page 1: ...Light Ventilation Kits Stock Ref N LuminAir Turbo SKL 453419C LuminAir Turbo SKT 453422C Installation and Wiring Instructions 220 240V 50Hz Kit comprises of Luminair turbo L or T mains fan SELV light assembly with white bezel Lighting transformer 90 bend 6 metres of flexible duct Quick fix wall grille 4 duct ties ...

Page 2: ...ld only be used in conjunction with the appropriate Vent Axia products E It is recommended that the connection to the fan connecter terminals is made with flexible cable F When the Fan is used to remove air from a room containing a fuel burning appliance precautions must be taken to avoid back flow of gases into the room from the open flue of gas or other appliance Ensure that the air replacement ...

Page 3: ...the securing clamps allow sufficient clearance to accommodate the ceiling thickness Position the securing clamps against the lamp housing and fit the LuminAir Vent Light through the hole Retighten the screws to clamp the Vent Light in place As an alternative the unit may be held in place with plugs and fixing screws using the fixing holes provided Line up the 3 Clips on the 90 bend and clip it to ...

Page 4: ...Y DURING THE INSTALLATION OR MAINTENANCE N B THE TURBO FANS ARE DOUBLE INSULATED AND CARRY A MARK THERE ARE NO EARTH TERMINALS AND THESE FANS MUST NOT BE EARTHED 1 Remove terminal box cover screws and put to one side Fig 9 2 Select and follow the appropriate wiring diagram Fig 10 11 adjust the speed setting Fig 14 if required The fan is factory set at high speed 3 Check all connections have been m...

Page 5: ...mall flat bladed screwdriver Fig 13 Before adjusting the timer switch off the Mains Supply Remove the fan terminal box cover and retain screws To INCREASE the operating time turn the adjuster CLOCKWISE To REDUCE the operating time turn the adjuster ANTI CLOCKWISE Replace the fan terminal box cover Speed Adjustment The fan has three speeds which are selectable by changing the position of the jumper...

Page 6: ...NTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE 1 At intervals appropriate to the installation the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits The Turbo fan has sealed for life bearings which do not require lubrication Lamp Replacement The LuminAir is specially designed for use with the supplied 12V DC LED lamp rated at 3W ...

Page 7: ...or CTRL 1 00 0 95 Control Typology Manual Control Clock Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs N A N A Mixing Rate of Non Ducted BVUs not intended to be equipped with one duct connection on either supply or extract air side N A N A Position and description of visual filter warning for RVUs ...

Page 8: ...nst faulty material or workmanship In the event of any part being found to be defective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Has not been connected to an unsuitable electricity supply The correct electricity supply voltage is shown on the product...