Vent-Axia Lo-Carbon SOLO Plus SELV HT Installation And Wiring Instructions Download Page 5

 
 

1. SELECTING THE CONSTANT TRICKLE OPTION - 

Switch dip switch 2 into the ON position to activate the 

constant trickle operation. To disable the constant trickle option, move dip switch 2 into the OFF position. (Fig 7).

 

 

2. SELECTING THE TRICKLE SPEED (if enabled) 

This will determine the speed at which the fan will run continuously if the constant trickle speed option is enabled (1 
above).  

 

Low trickle speed – Switch dip switch 1 into the OFF position (Fig 7). 

 

High trickle speed – Switch dip switch 1 into the ON position (Fig 7). 

 

3. SELECTING THE INSTALLATION RUNNING MODE  

This will determine the speed at which the fan will run when activated by either the Pull-cord/LS line/Humidity/PIR. 
 

 

Wall mode – Switch dip switch 3 into the OFF position (Fig 7). 

 

Ducted mode – Switch dip switch 3 into the ON position (Fig 7). 

 
4. SELECTING THE DELAY-ON OPTION

 

(T and HT models)

 - Switch dip switch 4 into the ON position to activate 

the delay-on feature. This will prevent the fan from going to boost for approximately 2 minutes. If the Switch Live is 
disconnected (switched off) within this period the fan will not boost. If the Switch Live is still active after the period the 
fan will boost (Fig 7). 

 
5. TIMER ADJUSTMENT (T, HT, TM models) 

The overrun time period is factory set to 15 minutes. The overrun time period may be adjusted from 5-30 minutes 
by altering the adjuster on the control PCB [T] (Fig 7). 

 

i. 

To REDUCE the operating time, turn the adjuster [T] ANTI-CLOCKWISE (Fig 7). 

ii. 

To INCREASE the operating time, turn the adjuster [T] CLOCKWISE (Fig 7). 

 
 
 

6. HUMIDITY ADJUSTMENT (HT model) 

The fan’s Humidity Set-Point is factory set to switch the fan on at 72%RH (Fig 7). 

 

i. 

To LOWER the Set-Point, turn the Humidity Adjuster [H] ANTI-CLOCKWISE. This makes the fan more 
sensitive to RH%, i.e. the fan will come on at a lower RH% (Fig 7). 

ii. 

To RAISE the Set-Point, turn the Humidity Adjuster [H] CLOCKWISE. This makes the fan less sensitive to 
RH%, i.e. the fan will come on at a higher RH% (Fig 7). 

 
C. WIRING.

 

 

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE 
POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. 
 

IMPORTANT 

 

The

 

Controller

 

MUST

 be surface mounted to allow air to freely circulate around the unit. When installed in a 

loft void it 

MUST

 

NOT

 be enclosed or covered with insulation. 

 

1.  Select and follow the appropriate wiring diagram (Fig 8-9) 
2.  It may be necessary to feed the mains cable around between the outside of the Base Housing and the Skirt to 

prevent the cable from being trapped. 

3.  Check all connections have been made correctly and ensure all terminal connections and cable clamps are 

securely fastened. 

4.  Ensure the impeller rotates and is free from obstructions. 
 

D. SERVICING AND MAINTENANCE. 

 

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED  

FROM THE POWER SUPPLY DURING MAINTENANCE. 

 

 
1.  At intervals appropriate to the installation, the fan should be inspected and if required cleaned to ensure there is 

no build-up of dirt or other deposits.  

2.  If a filter is fitted, remove the filter

 

and wash in warm soapy water. 

3.  Wipe the inlets and front face with a damp cloth until clean. 
4.  Once the filter is dry it can be replaced. 

The fan has sealed for life bearings, which do not require lubrication. 

Summary of Contents for Lo-Carbon SOLO Plus SELV HT

Page 1: ...ESE INSTRUCTIONS Lo Carbon SOLO Plus SELV Centrifugal Bathroom Toilet Fan Stock Ref N 427485B P 427486B T 427487B HT 427488B TM Installation and Wiring Instructions T IPX7 FAN FAN UNITS 12V DC SELV CLASS III CONTROLLERS 220 240V 50Hz MAINS SUPPLY CLASS II WITH 12V DC SELV OUTPUT ...

Page 2: ...le of disconnecting all poles having a contact separation of at least 3mm C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D The Fan should only be used in conjunction with the appropriate Vent Axia products E It is recommended that the connection to the fan connector terminals is made with flexible cable F When the Fan is used to remove air from a room con...

Page 3: ...y wall However the fan must not be placed where it could be submerged in water or regularly exposed to direct water spray e g from a shower head whether permanently fixed or movable A INSTALLATION PANEL MOUNTING Surface 1 Cut a 105mm hole through the panel ensuring that there is sufficient space for the product to be installed and that the filter If fitted can be removed for maintenance 2 Removing...

Page 4: ... Brown can be used 1 Cut a 115mm hole through the wall ensuring that there is sufficient space for the product to be installed and that the filter If fitted can be removed for maintenance 2 Insert the wall sleeve with the smaller diameter sleeve on the room side and cement both ends into position flush with the wall faces The wall sleeve should be angled downwards away from the fan to allow any co...

Page 5: ...LOCKWISE Fig 7 6 HUMIDITY ADJUSTMENT HT model The fan s Humidity Set Point is factory set to switch the fan on at 72 RH Fig 7 i To LOWER the Set Point turn the Humidity Adjuster H ANTI CLOCKWISE This makes the fan more sensitive to RH i e the fan will come on at a lower RH Fig 7 ii To RAISE the Set Point turn the Humidity Adjuster H CLOCKWISE This makes the fan less sensitive to RH i e the fan wil...

Page 6: ...6 Fig 3 Surface mounting screw hole locations Fig 1 Removing the grille Fig 2 Attaching the spigot Fig 4 Converting outlet spigot for side exit and recess mounting ...

Page 7: ...M model To remove the cover on TM models the sensor lead must be disconnected Timer adjuster T HT TM Models To reduce time Turn anti clockwise To increase time Turn Clockwise Humidity adjuster HT Model To LOWER the set point Turn Anti clockwise To RAISE the set point Turn clockwise Fig 5 Recess mounting clips In 3 positions LED position Dip switch settings Cable clamp must be used with surface wir...

Page 8: ... diagram IMPORTANT On first power up the fan will run through its initialization routine On T HT TM models the fan will switch on and off during this routine Including the LED Once complete after approximately 2 minutes the fan will run as normal ...

Page 9: ...logy CTRL Typology Control Factor CTRL 1 00 0 95 0 65 0 65 Control Typology Manual Control Clock Control Local Demand Control Local Demand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs N A N A N A N A Mixing Rate of Non Ducted BVUs not intended to be equipped with one duct connection on either sup...

Page 10: ...10 Notes ...

Page 11: ...11 Notes ...

Page 12: ...eglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your original supplier or nearest Vent Axia Centre by post or personal visit Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and p...

Reviews: