Vent-Axia ATQ 400-14C Installation And Wiring Instructions Download Page 6

6

A
B

DC
E

R

E

MOT

E

 V

ISU

AL

CONT

R

O

L

LE

R

CONNECT

IO

N

S

FA

N

 1

FA

IL

FA

N

 2

FA

IL

24

V A

C

E

L
NL

1
NL

2

L

3

SG

S1

FG

FS

K

A

A

K

LED 1

LED 2

SE

NS

OR

C

O

NN

ECT

IONS

24

0V

 

IN

PUT

24

0V

 

IN

PUT

IN

S

E

R

T LI

NK

 FOR

 

2

4HR

 CHANGE 

OV

ER

(I

T

C

-D

S ONLY)

LK1

ITC (Stk

 Ref 10

14 200)

ITC-DS 

(Stk R

ef 1

03

 14 210)

TK

TK

L3

L2

L1

N

FA

N 1

 

OU

TP

U

T

L2

L3

TK

TK

FA

N 2

 

OU

TP

U

T

N

L1

4

2

6

1

3

5

23

95

96

24

A1

E

A2

E

5

3

1

6

4

2

95

A2

A1

24

23

96

240 V

o

lt D.

O.

L.

 S

ta

rt

er 

A sui

tabl

si

ze

overl

oad 

relay mus

t b

e

 

fit

ted t

o

 pr

ovid

e mo

to

prot

ect

io

n

.

N.

B

. Li

nks bet

ween 

te

rm

in

al

to

 95,

 3 t

o

 6,

 5 t

o

 A

2

 an

 2

3

 to

 

96 m

u

st

 be 

fit

ted and

 th

lin

bet

ween t

e

rm

inal

s 24 

to

 9

6 mu

st

 

be 

R

E

M

O

VED

.

240 V

o

lt D.

O.

L.

 S

ta

rt

er 

A sui

tabl

si

ze

overl

oad 

relay mus

t b

e

 

fit

ted t

o

 pr

ovid

e mo

to

prot

ect

io

n

.

N.

B

. Li

nks bet

ween 

te

rm

in

al

to

 95,

 3 t

o

 6,

 5 t

o

 A

2

 an

 2

3

 to

 

96 m

u

st

 be 

fit

ted and

 th

lin

bet

ween t

e

rm

inal

s 24 

to

 9

6 mu

st

 

be 

R

E

M

O

VED

.

1

 Ph

as

e

 Supply

(2

20-

240

V 5

0H

z)

~

E

N

L

E

U1

L

U2

N

U2

N

E

U1

L

EXTRA LOW VOLT

A

G

WIRIN

G

 UP TO 25m L

O

NG

Fig. 4

ATQ ACOUSTIC SINGLE PHASE (WITHOUT TK CONNECTIONS) FAN WIRING DETAILS

STOCK REFERENCE NUMBER:
ATQ 500-14C.

NOTE: The ITC and ITC-DS controller operate by detecting the current flowing to the fan. If it is necessary to switch
the fan On/Off for any reason; e.g. fan Off at night, this switch operation must be done via the ITC and ITC-DS
controller by making or breaking a contact connected across S1-SG. Otherwise a fan failure will be registered.

Summary of Contents for ATQ 400-14C

Page 1: ...TRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS READ AND SAVE THESE INSTRUCTIONS ACOUSTIC TWIN FAN Stock Ref N ATQ 100 12C ATQ 200 12C ATQ 400 14C ATQ 125 12C ATQ 250 12C ATQ 500 14C ATQ 150 12C ATQ 315 1...

Page 2: ...rt duct runs terminating within 1 5m must incorporate suitable guards unless the fan is mounted higher than 2 3m J This fan should not to be used where it is liable to be subject to direct water spray...

Page 3: ...should be inspected and cleaned to ensure there is no build up of dirt or other deposits on the impeller or the motor Caution do not dislodge any balance weights which may be fitted to the impeller If...

Page 4: ...UTPUT L2 L3 TK TK FAN 2 OUTPUT N L1 U2 N U1 L U2 N E TK TK Fig 2 ATQ ACOUSTIC SINGLE PHASE FAN WIRING DETAILS STOCK REFERENCE NUMBERS ATQ 100 12C ATQ 125 12C ATQ 150 12C ATQ 160 12C ATQ 200 12C ATQ 25...

Page 5: ...7 103 14 105 103 14 103 1 Phase Auto Transformer Speed Controller L N L N Fuse L1 L2 N1 E E Fig 3 ATQ ACOUSTIC SINGLE PHASE FAN AND AN AUTO TRANSFORMER WIRING DETAILS STOCK REFERENCE NUMBERS ATQ 100 1...

Page 6: ...4 to 96 must be REMOVED 240 Volt D O L Starter A suitable sized overload relay must be fitted to provide motor protection N B Links between terminals 1 to 95 3 to 6 5 to A2 and 23 to 96 must be fitted...

Page 7: ...provide motor protection E A1 23 95 N L2 L3 L2 L1 N TK TK L3 E A2 24 5 96 6 1 3 2 4 23 A1 95 24 A2 96 240 Volt D O L Starter A suitable sized overload relay must be fitted to provide motor protection...

Page 8: ...the United Kingdom contact your local supplier Vent Axia guarantees its products for two years from the date of purchase against faulty material or workmanship In the event of any part being found to...