WIRING.

 

 

WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM 
THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. 

 

 

THE ACM FANS ARE DOUBLE INSULATED AND CARRY A        MARK. THERE ARE NO EARTH TERMINALS 
AND THESE FANS MUST NOT BE EARTHED. 

 

1.  Remove terminal box cover & screws and put to one side Fig. 9 
2.  Select and follow the appropriate wiring diagram (Fig. 10-11). 
3.  Check all connections have been made correctly and ensure all terminal connections and cable clamps are 

securely fastened. (Fig 12) 

4.  The cable entry must be made using the cable grommet provided 
5.  Replace terminal box cover & screws Fig.13 
6.  Ensure the impeller rotates and is free from obstructions  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

     

 
    

(Timer models cannot be used with a speed controller) 

 
 
 

 

 

 

Timer Adjustment. 
 

The fan must be wired to a remote switch (e.g. light switch). 
When switched ‘ON’, the fan will operate at the selected 
speed, and will continue to run for a preset time after the fan 
is switched ‘OFF’. The timer is factory set at 15 minutes 
approx. The overrun time period can be adjusted from 3-25 
minutes by altering the adjuster on the control PCB with the 
use of a small flat bladed screwdriver. Fig 13 

 

Before adjusting the timer, switch off the Mains Supply. 

 

Remove the fan terminal box cover and retain screws 
To INCREASE the operating time, turn the adjuster 

CLOCKWISE

To REDUCE the operating time, turn the adjuster

 ANTI-CLOCKWISE

.  

Replace the fan terminal box cover.

 

 
 

 

 

13 

12 

Summary of Contents for ACM100 B

Page 1: ...IONS ACM In Line MIXED FLOW FANS Stock Ref N ACM100 B 17104010D ACM100 T 17104020F ACM125 B 17105010D ACM125 T 17105020C ACM150 B 17106010C ACM150 T 17106020D ACM160 B 17107010B ACM160 T 17107020B ACM200 B 17108010C ACM200 T 17108020B Installation and Wiring Instructions 220 240V 50Hz IP44 ...

Page 2: ...y and MUST be installed by a suitably qualified person B The Fan should be provided with a local double pole isolator switch having a contact separation of at least 3mm C Ensure that the mains supply Voltage Frequency and Phase complies with the rating label D The Fan should only be used in conjunction with the appropriate Vent Axia products E It is recommended that the connection to the fan conne...

Page 3: ...d it should be fully extended to obtain the best results Position the fan at the highest point on the system with both ducting runs sloping downwards from this point The airflow direction is indicated on the rating label with an arrow pointing in the direction of the airflow In circumstances where an excessive amount of moisture is present in the air then a condensation trap should be installed Re...

Page 4: ...e terminal box cover screws Fig 13 6 Ensure the impeller rotates and is free from obstructions Timer models cannot be used with a speed controller Timer Adjustment The fan must be wired to a remote switch e g light switch When switched ON the fan will operate at the selected speed and will continue to run for a preset time after the fan is switched OFF The timer is factory set at 15 minutes approx...

Page 5: ...OT be used with the timer version C OVER HEATING PROTECTION The fan motor is fitted with Thermal Overload Protection This is a one shot thermal fuse In the event of a fault condition the fan will be automatically switched off If this occurs isolate the fan and call your service engineer D SERVICING AND MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPP...

Page 6: ...ace Velocity m s Design Flow Rate N A N A N A N A N A Nominal External Pressure Δps ext in Pa 71 74 92 92 167 Internal Pressure Drop of Ventilation Components Δps int in Pa N A N A N A N A N A Additonal Internal Press Drop of Non Ventilation Comp Δps add Pa N A N A N A N A N A Static Eff of fans used in accordance with Regulation EU No 327 2011 TBC TBC TBC TBC TBC Declared Max Internal External Le...

Page 7: ...A N A Face Velocity m s Design Flow Rate N A N A N A N A N A Nominal External Pressure Δps ext in Pa 71 74 92 92 167 Internal Pressure Drop of Ventilation Components Δps int in Pa N A N A N A N A N A Additonal Internal Press Drop of Non Ventilation Comp Δps add Pa N A N A N A N A N A Static Eff of fans used in accordance with Regulation EU No 327 2011 TBC TBC TBC TBC TBC Declared Max Internal Exte...

Page 8: ...fective the product will be repaired or at the Company s option replaced without charge provided that the product Has been installed and used in accordance with the instructions given with each unit Has not been connected to an unsuitable electricity supply The correct electricity supply voltage is shown on the product rating label attached to the unit Has not been subjected to misuse neglect or d...

Reviews: